9 Troubleshooting

The fault LED indicates that a signal is being received, but the signal contains enough faults to make
the port fail and go into bypass mode.

Port LEDs on the ATTO FibreCenter are
generally lighted if the port is enabled through the
Setup CLI command and an active device is
connected to the port. However, if you want to test
your configurations without having active devices
attached to the ports, enter the command Switch-

Forcemode while in the command line interface.
If the FibreCenter is not in force mode, however,
the port LEDs will behave as illustrated in the
table below.

LED

If LED is illuminated

If LED is not illuminated

OnLine

Port is on-line and functioning properly

No cable connected

Cable connected, but no device or host connected to cable

Cable connected between hub and connected device or
host, but the device is powered off

Fault

See information below

ATTO FibreCenter port is operating properly

Power A

ATTO FibreCenter is receiving power
through power supply A

Power supply A is not installed or turned on

A power supply is active, but the FibreCenter is not receiving
power through power supply A

Power B

ATTO FibreCenter is receiving power
through power supply B

Power supply B is not installed or turned on

A power supply is active, but the FibreCenter is not receiving
power through power supply B

Fault LED

Condition

ON

Port has been taken off-line, because it is not receiving proper signals due to the following:

Port is receiving bad / discontinuous signals

Bad cables

Device connected to the port is powered on, but failed

Cable may be too long / signal has deteriorated

SFP fault – an internal fault within the SFP connected to the port requires replacement.