How to operate, E. program lock, D. programming double or treble quantity pad – Panasonic NE2156 User Manual

Page 11: 9 - english

Advertising
background image

- 9 -

English

How to Operate

NE-2156-2/NE-1656

E. PROGRAM LOCK

INSTRUCTION

DIGITAL DISPLAY WINDOW

PAD

1

Keep the door closed.

Digital Display Window must be blank.

2

Press Prog pad until “PROG”, “P” and “L” appear. (more than five
seconds)

“PROG”, “P” and “L” will appear.

PROG

In Program Lock mode:
• The oven is started by pressing the desired Number/Memory pad. There is no need to press Start pad.
• Opening the door cancels the remaining time on the program.
• The oven can not be programmed or run manually until the program lock is released.

To Activate Program Lock:

INSTRUCTION

DIGITAL DISPLAY WINDOW

PAD

2

Press Prog pad.

“PROG” will start to blink.

PROG

4

Press Double Quantity pad.

The currently programmed magnification number will appear.

Note: 1.6 times is preset at factory.

x

2

PROG

5

Press Number/Memory pads “1” and “5”.

The programmed magnification number will appear.

1

5

PROG

6

Press Prog pad.

“PROG” will stop blinking.
This means that you have completed programming.

PROG

• Three seconds later, Digital Display Window will go blank.

Note:
• If you want to program your desired magnification number for treble quantity, repeat as above, using Treble

Quantity pad instead of Double Quantity pad.

3

Press Number/Memory pad “5”.

The selected pad number will appear and currently programmed
information will be indicated.

5

PROG

1

Example: To program 1.5 times of heating time for double quantity into Number/Memory pad “5”

1

Keep the door closed.

Digital Display Window must be blank.

D. PROGRAMMING DOUBLE OR TREBLE QUANTITY PAD

THE OVEN CAN NOT BE PROGRAMMED WHEN PROGRAM LOCK IS ACTIVATED! (see page 9-10)
DO NOT OPEN THE DOOR WHILE PROGRAMMING!

Advertising