Time code ext, rec run, free run, regen – Panasonic FS-100 User Manual

Page 79

Advertising
background image

FS-100 Functions

FS-100 Portable DTE Recorder

61

TIME CODE EXT, REC RUN, FREE RUN, REGEN

The following are timecode (

TC

) functions.

TC EXT

Group Default

Records the incoming source timecode. If the timecode is not

running, the FS-100 records the same timecode number in

each recorded frame. Choose

TC EXT

mode to clear any stored

number.

TC REC RUN

In this mode, after a power cycle, the FS-100 starts its TC

record count using the

TC SET

value. Later recordings add to

the last value recorded. A power cycle resets the TC record

value to the

TC SET

value.

TC FREE RUN

This function causes the FS-100 to begin counting from the

value stored by

TC SET

.

A number entered through

TC SET

is not stored and

available to the FS-100 until exiting

TC SET

. Only then does

the FS-100 begin counting using that number.

TC REGEN

When the FS-100 powers up in

TC REGEN

mode, it:

Reads the timecode of the last track recorded.
Adds 1 to the number.
Stores the new timecode as the number that will be

assigned to the first frame of the next recording session.

If the drive is empty, i.e. no existing recordings with, the

FS-100 uses the

TC SET

value.

TC SET and UB SET Can Be Set at the Same Time
Both parameters, TC SET and UB SET, may be set and are not mutually
exclusive as in some groups, i.e. LCDLIGHT.

TC EXT Recommended for Pull-down Applications
If the recording signal contains pull-down information in 720/60p format,
the frame flag information contained is preserved in TC EXT mode and
is required for the editing process.