Visual view 13.5 – Merrychef eikon e5 User Manual

Page 25

Advertising
background image

Service & Parts Manual original Instructions

Part Number 32Z3814 US

Issue 1

25

SER

VICING

E

VISUAL VIEW

13.5

Select VISUAL VIEW (E) to check the main oven

13.5.1
components. Select a component symbol to switch
on (red), select again to increase the level or turn off
(green).

Remove the front air intake filter, the colour

13.5.2
should change from green to red on the display
indicating that the magnetic reed switch circuit for the
air intake filter is operating. Replace the filter and the
colour should change back to green.

Open the oven door and check the colour

13.5.3
changes from green to red on the display to check
the door microswitch/interlock circuit is operating.
Place door spacers onto the oven door (refer to Door
Interlock Adjustment (Testing Components section)
for details), close the door and check the colour on
the display. Green indicates the door adjustment is
ok, red indicates that the Door Interlock Adjustment
procedure must be completed.

Select the cooling fan and check it’s operating

13.5.4
correctly.

Place a microwave safe container of water into

13.5.5
the oven, close the oven door and select a magnetron
to test the current draw at maximum output, this
will time-out after 30 seconds. For dual magnetron
models, test the magnetrons individually and together.
Using heat proof gloves, remove the container and
close the oven door.

Select the Convection Fan and check it is

13.5.6
operating correctly.

Select the Heating Element, it increases to

13.5.7
maximum temperature then cycles (the Convection
Fan is on by default). Check the cavity temperature
and heater element current draw at maximum are
correct.

Advertising