Service & Parts Manual original Instructions

Part Number 32Z3814 US

Issue 1

5

Heater Element

Catalytic Converter*

Convection Fan

(Top View)

PR

ODUC

T

DE

TAILS

PRODUCT OVERVIEW & FUNCTIONS

2

CONSTRUCTION
Stainless Steel. cavity and casework.

CONTROL SYSTEM
Colour touchscreen, icon driven.
Storage for up to 1024 programs with 6 stages per

cooking program providing a user instruction for

each stage.
USB memory stick data transfer.
Support for optional remote communications

Ethernet module.
Safety system: ensures control area temperature is

within limits.

MICROWAVE POWER
Two magnetrons.
Distribution system, rotating passive antennae.
Microwave settings, off or 5-100% in 1% increments.
Safety system: agency approved monitored

interlock door system, current monitoring and

overheat detection for magnetrons.

CONVECTED HEAT
Temperature settings 0°C off and from 100°C to

250°C in 1° C steps.
Distribution system, convection fan.
Safety system: oven cavity overheat detection.

How it works:
The convection fan (1) draws air from the oven cavity,

circulating it over the heating elements (2) to obtain the set

temperature and through the catalytic converter (3)* to clean

the air before returning it to the oven cavity.
* e5C models only.

Start up Sequence
With the oven switch in the OFF position and the

mains power ON, the BTS & SRB boards boot up.

When the oven switch is turned ON the splash

screen briefly displays oven information and the

cabinet cooling fan is activated.
After completing a successful logic test, the safety

relay is energised and the oven preheats or displays

a preheat temperature choice. Once preheated the

oven displays the main menu if in FS mode or a

recipe selection if in QSR mode.
Shutting Down Sequence
When oven switch is turned OFF the screen displays

‘Shutting Down’ and the cooling fan operates until

the cabinet temperature has been sufficiently

reduced (cavity temperature of 50C).
The safety relay is de-energised and the BTS & SRB

boards remain active.