Control module (upm) led lights – Power Soak 33529 Skewer Wash Owner's Manual User Manual

Page 22

Advertising
background image

18

Control Module (UPM) LED Lights

The Universal Programming Module (UPM) is mounted to the inside
surface of the control enclosure cover. This device has indicator lights
to aid in troubleshooting. To view this device the control panel cover
must be opened by removing the two screws at the top of the control
panel face.

Examination of the UPM lights will require that the
power is turned on while the control panel door is
open. Be aware that the components inside the
control panel operate with high voltage and must not
be touched while the power is turned on. Touching
the high voltage connections will result in sever
electrical shock and will cause serious injury or
death.


The UPM has six LEDs mounted on its top edge. The function of each
LED is as follows, starting from the right-most LED:

#1 -

Power On

#2 -

Error Code

#3 -

Wash Tank Low-level Sensor

#4 -

Wash Tank Upper-level Sensor

#5 -

Sanitizer Tank Low-level Sensor

#6 -

Sanitizer Tank Upper-level Sensor


For an explanation of the sensor lights call the Power Soak service
department (800-444-9624

), please note the “Error Code” (if any) that

can be identified by observing LED #2 on the UPM. If there is a control
logic error, LED #2 will flash with a “blinking” pattern. For example:

A

_“symbol represents a “long” flash

A

.” symbol represents a “short” flash

_ _ _ . => Water Level Problem
_ _ _ . . => Temperature Sensor Problem
_ _ _ . . . => Over-Current Problem


Please have this “Error Code” information available prior to calling Power
Soak Systems

*

*
*

Important

* indicates lights that
must be illumined for the
wash pump to operate.

Advertising