Plumbing requirements – Power Soak 33638 SILVERWARE WASHER OWNER'S MANUAL User Manual

Page 13

Advertising
background image

13

• Built-in units must have their control box brackets

mounted to the underside of the dish table in which
they are installed. If no acceptable location exists
on the underside of the dish table, the control box
may be mounted to the front of the wash tank. To
do this, remove the acorn nuts from the studs on
the wash tank, place the control box against the
tank, and replace the acorn nuts. Once mounted,
water-tight flexible conduit must be installed
between the control box and the motor junction box
and also between the control box and a wall
mounted junction box or disconnect. The wall-
mounted device must be NEMA 4X or IP67 rated
and must be supplied by a dedicated circuit. All of
these wiring tasks must be performed by a licensed
electrician.

Plumbing Requirements

The plumbing required for your system depends on the
type of system you have purchased:

• Mobile units must have a floor sink nearby that they

can be moved to for emptying waste water. In
addition, some mobile units are equipped with
faucets that will require a temperature regulated 1/2
NPT potable water flexible connection.

• Free-standing stationary units and built-in units

must have their drains permanently connected to
the building scullery sewer system. In addition,
these units are equipped with faucets that will
require a temperature regulated 1/2 NPT potable
water connection.

Electrical installation shall conform to all applicable local
wiring codes. All field connections must be liquid tight and
readily accessible for inspection after installation without
moving the machine or its accessories.