TROUBLESHOOTING

Issue

Possible Cause(s)

Resolution


F1: blower running

Status bad

- oven power interrupted.

- blower motor not running.

- Verify wall circuit breaker is on. reset the

breaker and then power the oven on.

- Place the oven in the off state and unplug

the oven – leave for two minutes. re-plug in

the oven, switch on the isolator/main power

supply, and press the “on/off” soft key.

- Call Customer Support.

F2: Cook
Temperature Low

- oven power interrupted.

- Air nozzles on the top/bottom

of the cook cavity are clogged.

- oven door is out of alignment.

- Defective heater.

- blower motor not running.
- oven not fully warmed up.

- Verify wall circuit breaker is on. reset the

breaker and then power oven back on.

- open oven door and verify the air nozzles

on the top/bottom of the cook cavity are

clean and not clogged.

- open and close the door several times and

verify oven door is closed.

- reset high-limit located in the bottom left

corner of the oven rear wall. If the problem

persists, call Customer Support.

- Call Customer Support.
- repeat warmup and allow oven to idle

for five minutes.

F3: Magnetron
Current Low

- Microwave circuit defective.


- Call Customer Support.


F4: Door Monitor

Defective

- oven door switches are out of
order.

- Call Customer Support.

F5: Magnetron over

Temperature

- blockage of cool air into the
oven.

- rear cooling fan exhaust

guard(s) clogged.

- remove anything that may be obstructing

the flow of cool air into the oven.

- Check rear fans to see if they are free of

debris. Clean as required.


F6: EC Temp

- blockage of cool air into the
oven.

- rear cooling fan exhaust

guard(s) clogged.

- remove anything that may be obstructing

the flow of cool air into the oven.

- Check rear fans to see if they are free of

debris. Clean as required.

Advertising