Gas pressure chart, Natural gas, Propane gas – Alto-Shaam FRYTECH ASF-60G series User Manual

Page 10

Advertising
background image

The Alto-Shaam open gas fryer has been set to operate
with either natural gas or propane as indicated on the
fryer identification name plate.

The appliance and its individual shutoff valve must be
disconnected from the gas supply piping system during any
pressure testing of that system at test pressures in excess of 1/2

psi. The appliance must be isolated from the gas supply piping
system by closing its individual manual shutoff valve during any
pressure testing of the gas supply piping system at test pressures
equal to or less than 1/2 psi.

NOTE:

Customer/installer must provide manual gas

shut-off valve in accordance with local code
requirements.

G A S S P E C I F I C A T I O N S

D A N G E R

CONNECTING TO THE WRONG GAS
SUPPLY COULD RESULT IN FIRE OR
AN EXPLOSION CAUSING SEVERE
INJURY AND PROPERTY DAMAGE.

I N S T A L L A T I O N

Gas Fryer Operation & Care Manual • 8

Declared input (kW)

35.15

Gas Group

I

2H(20),

I

2E(20),

I

2E+(20/25),

I

2L(25),

I

3+(28-30/37),

I

3B/P(30),

I

3B/P(37),

I

3B/P(50),

I

3P(37),

I

3P(50)

Inlet pressure (mbar)

17.5 (NAT) and 27.5 (LP)

Declared setting pressure at the

outlet from the gas valve (mbar)

12.5 (NAT) and 25 (LP)

Main burner type

Infrared type with blower and venturi valve

Number of injectors

1

Main injector type

N/A

Main injector size and markings N/A
Main burner aeration opening

size

Variable pre-set at factory

Ignition

Direct spark electronic ignition

Inlet connection

20.995 mm male thread

GAS PRESSURE CHART

The fryer has been factory adjusted according to

the gas type specified on the fryer identification

name plate.

GAS FRYER TECHNICAL SPECIFICATIONS

Natural Gas

Min. Connected Pressure

5.0” W.C.

1.2 kPa

Max. Connected Pressure

14.0” W.C.

3.5 kPa

Gas Consumption

120 CFM

Gross Thermal Output

120,000 Btu/hr

Propane Gas

Min. Connected Pressure

10.0” W.C.

2.5 kPa

Max. Connected Pressure

14.0” W.C.

3.5 kPa

Gas Consumption

48 CFM

Gross Thermal Output

120,000 Btu/hr

INSTALLATION REQUIREMENTS

gas

connection

: 1/2

” npt

check

plumbing

codes

for

proper

supply

line

sizing

to

attain

minimum

burner

manifold

pressure

shown

:

natural

gas

: 5.0” W.C.

propane

gas

: 10.0” W.C.

maximum

inlet

pressure

: 14” W.C.

NOTE:

If a flexible gas line is used, it must be AGA

approved, commercial type and at least 3/4” I.D.

hood

installation

is

required

GAS SPECIFICATIONS

natural

gas

propane

gas

120,000 BTU/hr.

input

120,000 BTU/hr.

input

Category

I

2H

at 20 mbar for use in AT, DK, FI, IE, IT, PT, SE, CH.

Category

I

2E(20)

at 20/25 mbar for use in DE, LU.

Category

I

2E+(20/25)

at 20/25 mbar for use in BE, FR.

Category

I

2L(25)

at 25 mbar for use in NL.

Category

I

3+(28-30/37)

at 28-30/37 mbar for use in BE, FR, IE, IT, LU,

PT, CH.

Category

I

3B/P(30)

at 30 mbar for use in DK, FI, NL, SE.

Category

I

3B/P(50)

at 50 mbar for use in AT, DE, CH.

Category

I3P(37) at 37 mbar for use in FI, DE, IE, CH.

W A R N I N G

TO AVOID SERIOUS PERSONAL
INJURY, installation of this appliance
must conform to local, state, and
national codes; the current edition
of the American National Standard
Z223.1, National Fuel Gas Code, and
all local municipal building codes.
In Canada, installation must be in
accordance with Standard CAN/CSA
B 149.1 and Installation Codes - Gas
Burning Appliances, and local codes.

Advertising