Installation

Installing the Terminal

QTERM-A12 Terminal

17

Portrait
When looking at the front of the unit, the back panel serial port(s) should be facing left. Refer to
Figure 3 for an example of a landscape installation.

3. On the back of the panel, align the terminal mounting ring holes with the mounting studs,

and place the mounting ring against the back of the panel. Refer to Figure 3 for the loca-
tion of the mounting studs.

4. Install nuts and washers (supplied with the terminal) onto each of the six mounting studs.

Torque all nuts to 67.8 N cm (6 lbs in) to create a seal between the terminal gasket and the
panel. Avoid overtightening the nuts.

5.2.2

Modular Version Installation

The modular version installation steps are to be used with QTERM-A12 models that DO NOT
have a factory-installed front bezel.

Take the following steps to install the terminal.

1. Verify that the panel surface around the cutout is clean and free of rough edges. A gasket

built into the terminal seals against the panel surface. Dirt or imperfections on the panel
may prevent a proper seal.

2. Place the terminal over the panel cutout by aligning the terminal mounting holes with the

mounting studs of the panel. Ensure that the orientation is correct. The printed labels on

Figure 3

QTERM-A12 Mounting