Dmx pathfinder lr dmx pathfinder operations, Dmx distribution system - block diagram – Pathway LR Manual User Manual

Page 55

Advertising
background image

DMXPathfinder LR

DMXPathfinder Operations

54

To accommodate the above requirements, a typical DMX Distribution

System consists of the following major components:

.5

Remote DMX input stations; in the control room, on the stage, and

in other locations, for connection of control consoles or other DMX source units.

.6

Remote DMX output stations, located on FOH lighting positions,

onstage lighting pipes, and spaced evenly around the stage or studio, for
connection of DMX-controlled (receiving) equipment.

.7

One or more distribution rack(s), which provides the means of

patching inputs to outputs, and incorporates all necessary electronics and cable
terminations.

.8

A personal computer with patch editing software, which includes a

data link to the distribution rack(s) for transferring patch file and diagnostic
information to and from the rack.

This is block diagram of a typical DMX Distribution System (example is

CBC Toronto Studio 42).

SOUTH

CONTROL

ROOM

CROSSPOINT

ROUTER

DISTRIBUTION

RACK

16 INPUTS

172 OUTPUTS

NORTH

STUDIO

WALL

SOUTH

STUDIO

WALL

DIMMER

ROOM

PERSONAL

COMPUTER

CONTROL RM
STUDIO WALLS

DMX INPUT

STATIONS

DMX DISTRIBUTION SYSTEM - BLOCK DIAGRAM

DMX OUTPUT

STATIONS

DIMMER

RACKS

DMX

NON-DIMS

BATTEN

DMX

STATIONS

PLAK

DMX

STATIONS

WALL

DMX

STATIONS

6

3

3

3

1

2

2

104

144

16

8