Port status – Axis Communications Video Server AXIS 241SA User Manual

Page 44

Advertising
background image

44

AXIS 241QA/AXIS 241SA - Event configuration

7. details). Any detected motion within an active window is then indicated by red

peaks in the Activity window (the active window has a red frame).

8. Click Save.

Please use the online help

for descriptions of each available option.

Examples:

• Avoid triggering on small objects in the image by selecting a high

size level.

• To trigger motion detection as long as there is activity in the area, select a high

history level.

• To only detect flashing light, low

sensitivity can be selected. In other cases, a high sensitivity level is

recommended.

Port status

Under Event Configuration > Port Status, there is a list that shows the status for the

connected inputs and outputs of the AXIS 241QA/AXIS 241SA. This is for the benefit of an

operator, who cannot access the System Options section.

Example:

If the Normal state for a push button connected to an input is set to Open circuit, as long as the button is

not pushed, the state is inactive. If the button is pushed, the state of the input changes to active.

If there are parts of the Include window that you wish to exclude, click the
Configure Excluded Windows radio button and perform steps 1-6 above.
Click

Save.

Parameter

Object

Size

History

Sensitivity

High

Only very large objects
trigger motion detection

An object that appears in the region will
trigger the motion detection for a long
period

Ordinary colored objects against ordinary
backgrounds will trigger the motion
detection

Low

Even very small objects
trigger motion detection

An object that appears in the region will
trigger motion detection for only a very
short period

Only very bright objects against a dark
background will trigger motion detection

Default values Low

Medium to High

Medium to High

Advertising