Installation, Operation & Maintenance

HTV/HTD/HTH SERIES

Heat Controller, Inc.

Model Breakdown

Model Nomenclature – Two Stage Geothermal Heat Pump

HT = Heat Controller Two Stage

C

0 2 4

C

1

0

1

A L K

4 5 6

7

8

9

10

11

12

13

14

024

Unit Size

036

Return Air Flow Configuration

Voltage

C = CXM

Controls

B = Efficiency Upgrade
C = Microchannel Air Coil on 036

Revision Level

Heat Exchanger Options

Cabinet

Supply Air Flow &
Motor Configuration

HT

1 2

Series

V

3

V = Vertical Up Flow
H = Horizontal
D = Vertical Down Flow

Configuration

L = Left Return
R = Right Return

Water Circuit Options

048
060

0 = Residential

1 = HWG w/Internal Pump
0 = None

Supply

Configuration

Motor

K
N
P

W

HTV
HTD
HTH
HTH

Top

Down

Back

Straight

ECM
ECM
ECM
ECM

070

1 = 208-230/30/1

A = Copper Water Coil, Coated Air Coil
J = Copro-Nickel Water Coil, Coated Air Coil

TABLE OF CONTENTS

Model Nomenclature ..........................................2

Storage ...............................................................4

Pre-Installation....................................................4

Horizontal Installation .........................................5

Field Conversion of Air Discharge ......................7

Duct System Installation .....................................8

Condensate Piping Installation ...........................8

Vertical Installation........................................ 9-10

Water Connection Installation ...........................11

Ground Loop Applications ...........................11-12

Open Loop - Ground Water Systems ...............13

Water Quality Standards ..................................15

Hot Water Generator .................................. 16-18

Electrical - Line Voltage .............................. 19-20

Electrical - Low Voltage Wiring ................... 21-22

Accessory Connections ....................................22

Electrical - Thermostat Wiring ..........................23

ECM Blower Control ................................... 24-25

Blower Data ......................................................26

CXM Controls ...................................................27

Safety Features – CXM Control.................. 28-30

Unit Commissioning
And Operating Conditions ................................31

Unit Start-Up and Operating Conditions ...........32

Unit Start-Up Procedure ...................................32

Coax Pressure Drop Tables ..............................34

Unit Operating Conditions .......................... 35-36

Performance Data ...................................... 37-41

Preventive Maintenance ...................................42

Troubleshooting ................................................43

CXM Process Flow Chart .................................44

Functional & Performance
Troubleshooting .......................................... 45-46

Troubleshooting Form ......................................47

Refrigerant Circuit Diagram ..............................47

Revision History................................................48