Installation, Operation & Maintenance

HTV/HTD/HTH SERIES

Heat Controller, Inc.

ECM Blower Control

Table 5: ECM Board Tap Settings

Y

G

G

G

G

R

W

O

Y2

Y1

G

R

C

Y2

Y1

G

O

W

C

R
DH

AL1

A

A

AL1

SW1

SW2

SW3

SW4

SW5

SW6

SW7

SW8

SW9

OFF

ON

G

DEHUM

CFM

TB1

J1

S1

Thermostat
Input LEDs

CFM Counter
1 flash per 100 CFM

ECM Motor
Low Voltage
Connector

1/4" Spade

Connections

to CXM or

DXM Board

Thermostat

Connections

Dehumidification

LED

Fan Speed Selection DIP Switch

J01

AL

AL

A

G

Y1 Y2

O

W1 EM C

R

G

Y1

Y2

OW

1

E

M
NC

C
R

Hum

3

2

1

4

3

2

1

4

3

3

2

1

2

2

1

4

3

2

1

4

56

78

9
1

0

L

LED's

TB01

CFM

Dehumid

Norm

Norm

Te
s

t

(–)

(+)

CFM

Adjust

Aux

CFM

HP

CFM

Delay

1/4" Spade
Connections
to CXM or
DXM Board

Thermostat
Input LEDs

CFM Counter
1 flash per 100CF

ECM Motor
Low Voltage
Connector

Dehumidification
LED

Fan Speed Selection Jumpers

Thermostat
Connections

Figure 26a: ECM Version II Interface Layout

Figure 26b: ECM Version I Interface Layout

Figure 26c: ECM Version III Interface Layout

*

(&00RWRU
/RZ 9ROWDJH
&RQQHFWRU

6SDGH
&RQQHFWLRQV
WR&;0RU
';0%RDUG

&RPSUHVVRU
'LVFKDUJH6HQVRU

*

*

*

5

+RW:DWHU6HQVRU

*

+:*/('

&&

5

&

:

2

<

<

*

6: 6:



6:



6: 6: 6: 6: 6: 6:

2))

21

6: 6:



6:

+:*3XPS
5HOD\

<

&)0&RXQWHU
IODVKSHU&)0

< <

* 2 :

& 5 '+ $/ $

',36ZLWFKHV

7KHUPRVWDW
&RQQHFWLRQV

$/

$

*

'HKXPLGLILFDWLRQ
/('

Cooling settings: TT, TS Units

Heating settings: TT, TS Units

Aux/Emerg Heat settings: TT, TS Units*

*Residential Units

Version I

Version I

Version I

69243707

69243707

69243707

Tap

HP CFM

Tap

DELAY

Tap

AUX CFM

Setting

Jumper

SW1

SW2

Setting

Jumper

SW3

SW4

Setting

Jumper

SW5

SW6

1

1

ON

ON

1

1

ON

ON

1

1

ON

ON

2

2

ON

OFF

2

2

ON

OFF

2

2

ON

OFF

3

3

OFF

ON

3

3

OFF

ON

3

3

OFF

ON

4

4

OFF

OFF

4

4

OFF

OFF

4

4

OFF

OFF

CFM Adjust settings: TT, TS Units

Dehum Mode settings: TT, TS Units

Version I

Version I

69243707

69243707

Tap

CFM Adj

Tap

Dehumid

Setting

Jumper

SW7

SW8

Setting

Jumper

TEST

1

ON

ON

NORM

pins 1,2

-

2

ON

OFF

Dehumid

pins 2,3

+

3

OFF

ON

NORM

4

OFF

OFF

DIP Switch

Version II and III

(17B0019N01 & 17B0034N01)

DIP Switch

DIP Switch

ON

OFF

DIP Switch

DIP Switch

SW9

Version II and III

(17B0019N01 & 17B0034N01)

Version II and III

(17B0019N01 & 17B0034N01)

Version II and III

(17B0019N01 & 17B0034N01)

Version II and III

(17B0019N01 & 17B0034N01)

HT Units

HT Units

HT Units

HT Units

HT Units

Advertising