11 choosing the initial reset, Choosing the initial reset, Figure 19: machine identification – Kramer Electronics VS-162AVRCA User Manual

Page 46

Advertising
background image

KRAMER: SIMPLE CREATIVE TECHNOLOGY

MENU Commands Sequence

42

Figure 19: Machine Identification

8.11 Choosing the initial RESET

Choose to reset the machine

1

Current status

to the:

2

Factory default (resets to the pre-installed factory default state

(reloads the current setup)

3

Each VS-162AV unit ships in its factory default

)

To reset the machine, do the following:

1. Press the MENU button until you reach the initial RESET command.

The MATRIX Display shows the message:

initial RESET

yes -> TAKE, next -> MENU

2. Press the TAKE button.

The MATRIX Display shows the message:

Outkey 1: Current status

2: Factory default

3. Press the OUT button 2, for example, to reset to the factory default.

The TAKE LED blinks and the Displays show the messages:

Reset to factory default

Press TAKE to execute

WARNING

!!!!!

4. Press the TAKE button again.

The Displays show the messages:

Reset to factory default

confirm by pressing OUT # 7

WARNING !!!!!

5. Press the OUT # 7.

The machine resets to the factory default and the Displays show the first

messages of the reloading progress (as Figure 19 illustrates).

1 Without having to switch the power off and on
2 Sometimes called a “soft reset”
3 Each unit ships in its factory default state that is a 16x16 audio-video matrix, with all setups empty and each input
connected to its corresponding output (for example, 1-to-1)

Advertising
This manual is related to the following products: