2 connecting the rs-232 port, 1 determining the machine number, Connecting the rs-232 port – Kramer Electronics VS-88FO User Manual

Page 15: Section

Advertising
background image

12

VS-88FO - Connecting the VS-88FO

5.2

Connecting the RS-232 Port

You can connect to the VS-88FO using an RS-232 connection using, for example,

a PC. Note that a null-modem adapter/connection is not required.

To connect to the VS-88FO using RS-232:

Connect the RS-232 9-pin D-sub rear panel port on the VS-88FO to the

RS-232 9-pin D-sub port on your PC. Use a 9-wire straight cable (only pin

2 to pin 2, pin 3 to pin 3, and pin 5 to pin 5 need to be connected)

5.2.1

Determining the Machine Number

Each unit must be identified by a unique machine number (MACH #). Determine

the machine number

according to the following table.

When using a single unit, set the unit to Machine # 1.

A master unit must be Machine #1.

When connecting more than one VS-88FO, set a different Machine # for each unit.

The units do not have to be numbered sequentially but each unit must have a

unique machine number.

Mach #

DIP-SWITCH

1

2

3

4

1 (Single or

master unit)

OFF

ON

OFF
OFF

OFF
OFF

OFF
OFF

2

OFF

ON

OFF

OFF

3

ON

ON

OFF

OFF

4

OFF

OFF

ON

OFF

5

ON

OFF

ON

OFF

6

OFF

ON

ON

OFF

7

ON

ON

ON

OFF

8

OFF

OFF

OFF

ON

9

ON

OFF

OFF

ON

10

OFF

ON

OFF

ON

11

ON

ON

OFF

ON

12

OFF

OFF

ON

ON

13

ON

OFF

ON

ON

14

OFF

ON

ON

ON

15

ON

ON

ON

ON