Connecting the VS-88HD

14

Table 3: Machine # DIP-Switch Settings

Machine #

DIP-SWITCH

1

2

3

4

1 (Single or

master unit

1

OFF

ON

)

OFF

OFF

OFF

OFF

OFF

OFF

2

OFF

ON

OFF

OFF

3

ON

ON

OFF

OFF

4

OFF

OFF

ON

OFF

5

ON

OFF

ON

OFF

6

OFF

ON

ON

OFF

7

ON

ON

ON

OFF

8

OFF

OFF

OFF

ON

9

ON

OFF

OFF

ON

10

OFF

ON

OFF

ON

11

ON

ON

OFF

ON

12

OFF

OFF

ON

ON

13

ON

OFF

ON

ON

14

OFF

ON

ON

ON

15

ON

ON

ON

ON

Note: After changing the address, the device must be reset by turning OFF
and ON.

6.4.2 Setting the DIP-Switches

When controlling a unit via the RS-232 or RS-485 ports set the
DIP-switches on the rear of the unit.

Figure 5

and

Table 4

define the

DIP-switches

2

:

Figure 5: DIP-Switch Settings

Table 4: DIP-Switch Settings

DIPS

Function

Description

RS-485 Term

RS-485 line termination

OFF for no RS-485 line termination

ON for RS-485 120

Ω line termination

PROG

Firmware update

Set ON only to update device firmware

MACH # 1, 2, 3, 4

Self Address

Sets the MACHINE # (see section

6.4.1

)

1 A single or master unit can have the address 0 or 1

2 The default address is 0 (all DIP-switches are OFF)