Connecting the VS-88HD

19

19

3. Click OK.

The Device Properties window appears:

Figure 9: Device Properties Screen

4. If required, make changes and press Set. If not, click Close.

6.9

Controlling via the Ethernet Port

You can control the VS-88HD via RS-232/RS-485 or the Ethernet using the
Kramer K-Router application.

If you are controlling a standalone unit via RS-232 or the Ethernet,
configure the unit as master (Mach No. 1), see section

6.4.1

.

6.10 Using the Ethernet Reset Button

To reset Ethernet parameters to the factory defaults:

1. Turn the power switch OFF and then ON while pressing the ETH RESET

button.

2. The unit powers up and loads its memory with the factory default

definitions.

3. The unit also erases all stored presets, returns to the default Protocol 3000

and indicates “F-rst” on the 7-segment display.