5 connecting a pc or controller to the rs-485 port, 1 setting the address switches, 2 setting the line termination – Kramer Electronics VS-88HD User Manual

Page 19: Connecting a pc or controller to the rs-485 port, Setting the address switches, Setting the line termination

Advertising
background image

Connecting the VS-88HD

15

15

The RS-485 TERM DIP-switch is used only when the RS-485 port is
connected (see section

6.5

). The first and last units on the RS-485 line

(for example, the controller and the last VS-88HD) must be terminated;
the units in between must not be terminated.

Set the PROG DIP-switch ON only while updating the unit firmware,
otherwise the switch must be OFF.

6.5

Connecting a PC or Controller to the RS-485 Port

You can operate the VS-88HD via the RS-485 port from a distance of up to
1200 meters (3900ft) using any device equipped with an RS-485 port (for
example, a PC). For successful communication, you must set the RS-485
machine number and bus termination.

To connect a device with a RS-485 port to the VS-88HD:

• Connect the A (+) pin on the RS-485 port of the PC to the A (+) pin on

the RS-485 port on the rear panel of the VS-88HD

• Connect the B (–) pin on the RS-485 port of the PC to the B (–) pin on

the RS-485 port on the rear panel of the VS-88HD

• Connect the G pin on the RS-485 port of the PC to the G pin on the

RS-485 port on the rear panel of the VS-88HD

6.5.1 Setting the Address Switches

To set the address DIP-switches, as shown in

Figure 5

:

• Assign Master Machine #1 to the master unit with the address

0 or 1 set in the DIP-switches

• Assign a unique Machine # from 2 to 15 for each VS-88HD slave

unit using

Table 3

. The units do not have to be sequentially

numbered but they must have unique addresses

6.5.2 Setting the Line Termination

To ensure correct operation, the RS-485 line must be terminated at both
ends. The master unit may be located at any part of the line, but when it is at
the end of the line, the termination switch must be set ON.

To set line termination, as shown in

Figure 5

:

• For the VS-88HD units located at the ends of the RS-485 line, set

the RS-485 TERM DIP-switch ON

• For all other VS-88HD units in the middle of the line, set the RS-

485 TERM DIP-switch OFF