7 recalling an input/output configuration, 8 locking the front panel, 9 switching protocols – Kramer Electronics VS-88HD User Manual

Page 26: Recalling an input/output configuration, Locking the front panel, Switching protocols

Advertising
background image

KRAMER: SIMPLE CREATIVE TECHNOLOGY

Operating the VS-88HD

22

1. Press the STO button.

The STO button flashes.

2. Press one of the IN / OUT SELECT buttons.

The current configuration is stored in memory at the chosen preset #.

7.1.7 Recalling an Input/Output Configuration

To recall an input/output configuration, do the following:

1. Press the RCL button.

The RCL button flashes.

2. Press the appropriate IN / OUT SELECT button (the button #

corresponding to the preset #).
The chosen preset configuration is restored from memory.

Note: Recalling an invalid setup gives an error indication (see section

7.1.10

).

If you cannot remember which of the eight input/output configurations is
the one that you want, set the VS-88HD to the CONFIRM mode and
manually scan all the input/output configurations until you locate it.

7.1.8 Locking the Front Panel

Lock the front panel buttons to prevent unwanted key presses from
changing the existing setup.
• To lock the front panel, press and hold the LOCK key for three

seconds.
The LOCK key illuminates and the front panel keys are inactivated

• To unlock the front panel, press and hold the illuminated LOCK

key until the light turns off.
The front panel keys are activated

7.1.9 Switching Protocols

You can operate the VS-88HD using either the KRAMER 2000 or the
default KRAMER 3000 serial protocol.
• To choose the Kramer 2000 protocol instead of the default Protocol

3000, press LOCK and OUT 2 at the same time.
LOCK flashes briefly if the change was made correctly

• To revert to the Kramer 3000 protocol, press LOCK and OUT 3 at

the same time.
LOCK flashes briefly if the change was made correctly