Figure 13: local area connection properties window – Kramer Electronics VP-790 User Manual

Page 34

Advertising
background image

VP-790 - Controlling the VP-790

29

29

7.3.1

Connecting the ETHERNET Port Directly to a PC (Crossover Cable)

You can connect the Ethernet port of the VP-790 to the Ethernet port on your PC,

via a crossover cable with RJ-45 connectors.

This type of connection is recommended for identification of the
factory default IP Address of the VP-790 during the initial

configuration.

After connecting the Ethernet port, configure your PC as follows:

1. Right-click the My Network Places icon on your desktop.

2. Select Properties.

3. Right-click Local Area Connection Properties.

4. Select Properties.

The Local Area Connection Properties window appears.

5. Select the Internet Protocol (TCP/IP) and click the Properties Button (see

Figure 13

).

Figure 13: Local Area Connection Properties Window

6. Select Use the following IP Address, and fill in the details as shown in

Figure 14

. You can use any IP address in the range 192.168.1.1 to

192.168.1.255 (excluding 192.168.1.39) that is provided by your IT

department.