Kramer protocol 3000 – Kramer Electronics PL-50 User Manual
Page 48
KRAMER: SIMPLE CREATIVE TECHNOLOGY
Kramer Protocol 3000
44
ALARM-OFF
Cmd Short
Description
Command Type
Permission
Set alarm OFF
PL-50
User
Usage:
Syntax
Response
ALARM-OFF
ALARM-OFF RESULT
ALARM-ON
Cmd Short
Description
Command Type
Permission
Set alarm ON
PL-50
User
Usage:
Syntax
Response
ALARM-ON
ALARM-ON RESULT
ALARM-ON?
Cmd Short
Description
Command Type
Permission
Query alarm status
PL-50
User
Usage:
Syntax
Response
ALARM-ON?
ALARM-ON 1/0
1/0= On OR Off
ALARM-START-AS
Cmd Short
Description
Command Type
Permission
Set alarm Relay mode start
PL-50
Administrator
Usage:
Syntax
Response
ALARM-START-AS 1/0
ALARM-START-AS 1/0 RESULT
1/0= Open/Close
ALARM-START-AS?
Cmd Short
Description
Command Type
Permission
Query alarm Relay mode start.
PL-50
User
Usage:
Syntax
Response
ALARM-START-AS?
ALARM-START-AS 1/0
1/0= Open/Close
ALERT-REG
Cmd Short
Description
Command Type
Permission
Alert Registration
PL-50
Administrator
Usage:
Syntax
Response
ALERT-REG? CHNL
ALERT-REG? CHNL ,EVENT ,ACTION
CHNL = (1-5)
EVENT = (TO_OFF,TO_ON,TO_FULL,TO_STBY,TO_NONE,ANY_CHANGE)
ACTION = (NO_ALERT,ALARM, ALL_ALERTS)