9 communication protocol, Communication protocol, Table 5: structure of the protocol – Kramer Electronics SP-12HD User Manual

Page 18: 9communication protocol

Advertising
background image

KRAMER: SIMPLE CREATIVE TECHNOLOGY

Communication Protocol

16

9

Communication Protocol

RS-232 communication between the SP-12HD and the PC is performed
using this protocol (VER 0.1). The protocol

1

The controller and the machine should be connected via a null-modem
connection, that is, if using a 9-pin D-sub port, connect pin 5 of the PC to
pin 5 of the machine, cross pins 2 and 3, that is, connect pin 2 of the PC to
pin 3 of the machine, and connect pin 3 of the PC to pin 2 of the machine.
On the PC side, short pins 4 and 6, and short pins 1, 7 and 8.

uses four bytes of information,

and transmission settings are 9600 baud, no parity, 8 data bits and 1 stop bit.

Table 5: Structure of the Protocol

MSB

LSB

INSTRUCTION

0

TO PC

I5

I4

I3

I2

I1

I0

7

6

5

4

3

2

1

0

Byte 1

DATA

1

D6

D5

D4

D3

D2

D1

D0

7

6

5

4

3

2

1

0

Byte 2

EXTENDED DATA

1

E6

E5

E4

E3

E2

E1

E0

7

6

5

4

3

2

1

0

Byte 3

MSBs

ADDR

1

E7

D7

1

1

0

0

0

7

6

5

4

3

2

1

0

Byte 4

Note that the MSBs of the DATA (D7) and the EXTENDED DATA (E7) are in the fourth byte.

Terminology:

 TO PC is the “DESTINATION BIT”
 I4..I0 is the “INSTRUCTION”
 D7..D0 is the “DATA”
 E7..E0 is the “EXTENDED DATA”


The destination bit, TO PC, is 0 when sending from the PC to the machine, or 1 when sending from the machine
to the PC.


1 This protocol complements Kramer’s “Protocol 2000” (Kramer’s switcher protocol), that is, the two protocols can co-exist

without disturbing one another (according to Protocol 2000’s definitions, the SP-12HD would be machine number 24).

Advertising