12

chimney above the Flashing, and also along

the vertical seam of the chimney pipe, which

is exposed to the weather. (Figures 14 and

15). Slide the Storm Collar down over the

chimney to the top of the Flashing. Tighten

and seal the Storm Collar against the sealant.

After installing sufficient Chimney Sections to

meet the height requirement, (Figure 1), snap

the Chimney Cap onto the top of the chimney.

The Chimney Cap can be removed for

chimney cleaning as described in the Chimney

Maintenance section of the instructions. Use

an Extended Roof Bracket if the chimney

extends more than 4 feet above the roof.

(Figures 18, and 19) in the Extended Roof

Bracket section. If you are located in heavy

snow country, a “splitter” should be fabricated

from heavy gauge sheet metal, and installed.

(Figure 16). This will route the snow around

the chimney, and protect it. This item is not

furnished by DuraVent.

11. Enclosures: Enclose chimneys where

they pass through occupied spaces, including

closets. Always maintain at least a 2 inch

clearance between the chimney and any

combustible surface. Interior enclosures may

be constructed with standard framing and

sheathed with sheetrock or plywood. Use Wall

Straps, if necessary, to maintain a minimum of

2 inches of air space between the chimney and

combustible materials.

OFFSET ELBOW INSTALLATION

Elbows are manufactured in 15° and 30°

angles measured from the vertical. A 30°

Elbow is the largest that can be used in an

offset. A 30° Elbow may not be combined with

a 15° Elbow to make a 45° offset for example.

Avoid Elbows if possible, since a totally vertical

chimney is more efficient. When Elbows

are necessary to avoid obstructions such as

rafters, ridgepoles, or joists, use no more than

CAP

SDP-C

Figure 15

APPLY SMALL BEAD OF NON-HARDENING

SEALANT ALONG SEAM SEAM OF CHIMNEY

PIPE SECTION

Figure 16

SPLITTER

SPLITTER

TOP VIEW

Figure 17

SDP-ES

SDP-E 15º / 30º

NOT MORE THAN 48 INCHES

SDP-P

RISE

SDP-P

OFFSET

Advertising