21 zero-clearance fireplace installations, Connection from appliance to chimney system – M&G DuraVent DuraPlus® User Manual

Page 21

Advertising
background image

21

ZERO-CLEARANCE FIREPLACE

INSTALLATIONS

1. Manufacturer’s Instructions: Carefully

read and comply with the manufacturer’s

installation instructions for your fireplace. Verify

that DuraVent’s DuraPlus chimney is approved

for use on your fireplace.

2. Base Plate: Attach a Base Plate to the

fireplace top with sheet metal screws. (Figure

31). A high temperature sealant may be used

if desired.

3. Chimney Sections: Attach a Chimney

Section to the Base Plate by twist-locking.

4. Completion: Install the remainder as

instructed for a standard Ceiling-Supported

installation, (less the Support Box). Always

maintain at least 2 inches of clearance to

combustibles, and enclose the chimney where

it passes through occupied areas.

CONNECTION FROM APPLIANCE

TO CHIMNEY SYSTEM

1. Single Wall Stovepipe: DuraVent’s

“DuraBlack” stovepipe is recommended,

if single wall stovepipe is desired. The

connection to the ceiling support box, or

wall thimble is made with a DuraBlack Slip

Connector (Part# 1670, 1770, or 1870, for

6-inch, 7-inch, or 8-inch pipe, respectively).

The beaded end of the slip connector slips into

the hole in the ceiling support or wall thimble.

Align the tabs on the slip connector with the

notches in the face of the support or wall

thimble, push the connector in, and twist to

lock it in. Further instructions for assembling

the DuraBlack pipe are contained in their

shipping cartons. Remember, the minimum

clearance to combustibles for single wall

stovepipe is 18 inches.

2. DVL: DuraVent manufactures DVL, which

is a double-wall connector pipe, which may

be positioned within 6 inches to a combustible

wall, and within 8 inches to a combustible

ceiling, provided the appliance installation

instructions permit this distance. In order

to join this type of connector to the ceiling

support, or wall thimble, a Close Clearance

Adaptor (Part #8674, 8774, or 8874, for

6-inch, 7-inch, or 8-inch pipe, respectively),

is required. The adaptor slips into the hole in

the ceiling support, or wall thimble. Align the

tabs on the adaptor with the slots cut into the

face of the ceiling support, or wall thimble,

push in, and twist to lock it in place. Detailed

instructions for assembling the remainder of

the close clearance system are included in the

shipping cartons.

Figure 31

CHIMNEY

SECTION

SHEET

METAL

SCREWS

BASE PLATE

(SDP-BP)

ZERO-CLEARANCE FIREPLACE

Advertising