Figure 27 – M&G DuraVent DuraPlus® User Manual

Page 17

Advertising
background image

17

diameter hole must be cut through the wall.

3. Install Wall Thimble: Insert the black

section of the Wall Thimble into the opening

in the wall from inside the room, and align

the nail holes with the studs. (Figure 26).

Do not nail the black thimble section at this

time. Attach the Tee to a 9-inch or 12-inch

Chimney Section by twisting until it is firmly

locked. If the wall is less than 6 inches thick,

use a 9-inch Chimney Section; if the wall is

between 6 and 9 inches thick, use a 12-inch

Chimney Section. From outside the building,

insert the Chimney Section into the hole until

the vertical part of the Tee is 2 inches away

from the outside of the wall, and the black

portion of the Wall Thimble and the Chimney

Section protrude into the room at least 2

inches. iMPORTAnT: in order to make a

safe connection, the female end of the

Chimney Section must fully contact the

inside face of the Wall Thimble. Remove the

Figure 26

5/16 x 3” LAG

SCREWS (6 REq)

NOT FURNISHED

14 1/2”

14 1/2”

8-PENNY NAILS (4) REq

SHIMS TO

MAINTAIN

CIRCULARITY

OF THIMBLE

(2) REq (NOT

FURNISHED,

MAY BE MADE

OF WOOD)

2 INCHES MINIMUM

DURA PLUS

CHIMNEY PIPE

TEE

SDP-T

2 INCHES MINIMUM

CLEARANCE

INTERIOR

PORTION OF

WALL THIMBLE

SDP-WT (BLACK)

OUTSIDE

VIEW FROM OUTSIDE

Figure 27

NOTE: IF SYSTEM ExITS

THRU WALL INTO GARAGE, AN

ENCLOSURE ISREqUIRED.

VENTILATED FLASHING

MUST BE USED

2 INCHES MINIMUM

ENCLOSURE

GARAGE

2 INCHES

MINIMUM

ACCESS DOOR

FOR CLEANING

Tee and Chimney Section from the wall, and

nail the Wall Thimble’s black section to the

studs with four 1-inch roofing nails. If the Wall

Thimble is going through a concrete wall, and

no framing members are available to which to

nail the black portion of the Wall Thimble to,

use masonry anchors to attach it. If a Tee-

Supported installation is being installed in a

garage, it must be enclosed. (Figure 27).

4. Seal Outside: From the outside, insert

the galvanized section of the Wall Thimble

through the wall and into the black section.

If it does not reach the black section, an

extension tube can be locally made from .018”

thick galvanized steel. Seal the flange of the

galvanized portion of the Wall Thimble to the

outside wall, using non-hardening waterproof

sealant, and fasten it to the wall with screws.

From the outside, slip the Chimney Section,

which is attached to the Tee, into the Thimble.

neVeR inSTALL SinGLe WALL STOVePiPe

ThROUGh The WALL ThiMBLe!

5. Install Tee Support: Remove the two

screws from the Tee Cleanout Cap, and detach

it from the Tee. Attach the Tee Support Straps

to the base with the nuts and bolts provided.