Commands 29, Ustatus, Ustatusoff – Konica Minolta Magicolor 2350EN User Manual

Page 33

Advertising
background image

Commands

29

Command

USTATUS

Syntax

@PJL USTATUS variable = value [<CR>]<LF>

Response

Syntax

@PJL USTATUS variable <CR><LF>

[1 or more lines of printable characters or

<WS>* followed by <CR><LF>]<FF>

Description Enables unsolicited status readback. Unsolicited status is

an automatic response sent by the printer whenever the
status is changed.

Variables allowed are
DEVICE—Response when device status changes. Choices
are ON, OFF, and VERBOSE.

JOB—Response when the print job is started, completed
or canceled. Choices are ON and OFF.

PAGE—Response whenever a page is fed into the output
tray. Choices are ON and OFF.

TIMED—Sets up a timed interval between automatic status
responses. Choices are 0 and 5 to 300 seconds. 0 is the
default (one status is returned).

Notes *<WS> stands for white space.

The VERBOSE setting returns all PJL parser errors and
warnings and should be used only during application devel-
opment.

USTATUS DEVICE=ON allows the printer to send
responses when any status changes occur.

Command

USTATUSOFF

Syntax

@PJL USTATUSOFF [<CR>]<LF>

Description Turns off all unsolicited status settings.

Notes You can use the USTATUS command to turn off individual

parameters.