Warning, Caution – Bryant EVOLUTION 577D----A User Manual

Page 12

Advertising
background image

12

OUT

TEE

NIPPLE

CAP

IN

C99020

Fig. 10 -- Sediment Trap

FIRE OR EXPLOSION HAZARD
Failure to follow this warning could result in fire, explosion,

personal injury, death and/or property damage.

S

Connect gas pipe to unit using a backup wrench to avoid
damaging gas controls.

S

Never purge a gas line into a combustion chamber. Never
test for gas leaks with an open flame. Use a commercially
available soap solution made specifically for the detection
of leaks to check all connections.

S

Use proper length of pipe to avoid stress on gas control
manifold.

S

If a flexible connector is required or allowed by authority
having jurisdiction, black iron pipe shall be installed at
furnace gas valve and extend a minimum of 2 in. (51 mm)
outside furnace casing.

S

If codes allow a flexible connector, always use a new
connector. Do not use a connector which has previously
serviced another gas appliance.

!

WARNING

8. Check for gas leaks at the field--installed and

factory--installed gas lines after all piping connections have

been completed. Use a commercially available soap solution
made specifically for the detection of leaks (or method
specified by local codes and/or regulations).

Install Electrical Connections

ELECTRICAL SHOCK HAZARD
Failure to follow this warning could result in personal

injury or death.
The unit cabinet must have an uninterrupted, unbroken

electrical ground. This ground may consist of an electrical

wire connected to the unit ground screw in the control

compartment, or conduit approved for electrical ground

when installed in accordance with NEC, NFPA 70 National

Fire Protection Association (latest edition) (in Canada,

Canadian Electrical Code CSA C22.1) and local electrical

codes.

!

WARNING

HIGH--VOLTAGE CONNECTIONS
The unit must have a separate electrical service with a

field--supplied, waterproof disconnect switch mounted at, or within
sight from, the unit. Refer to the unit rating plate, NEC and local

codes for maximum fuse/circuit breaker size and minimum circuit
amps (ampacity) for wire sizing.
The field--supplied disconnect may be mounted on the unit over

the high--voltage inlet hole (See Fig. 5 and 6).
NOTE:

Field supplied disconnect switch box should be

positioned so that it does not cover up any of the unit gas
combustion supply air louvers.
Operation of unit on improper line voltage constitutes abuse and

may cause unit damage that could affect warranty.

UNIT COMPONENT DAMAGE HAZARD
Failure to follow this caution may result in damage to the

unit being installed.

1. Make all electrical connections in accordance with NEC

NFPA 70 (latest edition) and local electrical codes
governing such wiring. In Canada, all electrical

connections must be in accordance with CSA standard
C22.1 Canadian Electrical Code Part 1 and applicable
local codes. Refer to unit wiring diagram.

2. Use only copper conductor for connections between

field--supplied electrical disconnect switch and unit. DO

NOT USE ALUMINUM WIRE.

3. Be sure that high--voltage power to unit is within

operating voltage range indicated on unit rating plate.

4. Insulate low--voltage wires for highest voltage contained

within conduit when low--voltage control wires are in

same conduit as high--voltage wires.

5. Do not damage internal components when drilling

through any panel to mount electrical hardware, conduit,
etc.

!

CAUTION

ROUTING POWER LEADS INTO UNIT
Use only copper wire between disconnect and unit. The high
voltage leads should be in a conduit until they enter the duct panel;

conduit termination at the duct panel must be watertight. Run the
high--voltage leads through the power entry knockout on the

power entry side panel. See Fig. 5 and 6 for location and size. For

single--phase units, connect leads to the black and yellow wires.
CONNECTING GROUND LEAD TO GROUND SCREW
Connect the ground lead to the chassis using the ground screw on
the control plate near the inducer switch (See Fig. 12).