Engineered applications, Surecross, Plug-and-play: configured kits – Banner American Products Wireless Network User Manual

Page 22: 3 miles, Analog & discrete, Flexpower, Systems, Discrete

Advertising
background image

SureCross

Plug-and-Play: Configured Kits

One box houses the preset Gateway, Node(s), accessories and hardware to get you up and running quickly.

The Gateway is configured to independently control I/O mapping for all devices within the kit.

Network traits are preset to provide discrete I/O on change of state and periodic reporting of analog I/O.

22

More information online at

bannerengineering.com

OFF

To

Control

Valve

DX80

Node

10-30V DC

3 miles

DX80

Node

DX81

Battery

Module

Flow

Sensor

10-30V DC

DX80

Gateway

3 miles

Model Number Frequency

Icon*

Gateway I/O

Node 1 I/O

Node 2 I/O

Node 3 I/O

Node 4 I/O

Data Sheet

DX80K9M6DP1

900 MHz

G

N

Modbus Enabled

Discrete

4 IN & 4 OUT

Discrete

4 IN & 4 OUT

129306

DX80K2M6DP1

2.4 GHz

G

N

DX80K9M6DP4

900 MHz

G

NN

NN

Discrete

4 IN & 4 OUT

Discrete

1 IN & 1 OUT

Discrete

1 IN & 1 OUT

Discrete

1 IN & 1 OUT

Discrete

1 IN & 1 OUT

129308

DX80K2M6DP4

2.4 GHz

G

NN

NN

Model Number Frequency

Icon*

Gateway I/O

Node 1 I/O

Node 2 I/O

Data Sheet

DX80K9M6MP1

900 MHz

G

N

Modbus Enabled

Discrete

2 IN & 2 OUT

Analog

2 IN & 2 OUT

Discrete

2 IN & 2 OUT

Analog

2 IN & 2 OUT

129312

DX80K2M6MP1

2.4 GHz

G

N

DX80K9M6MP2

900 MHz

G

N

N

Discrete

2 IN & 2 OUT

Analog

2 IN & 2 OUT

Discrete

1 IN & 1 OUT

Analog

1 IN & 1 OUT

Discrete

1 IN & 1 OUT

Analog

1 IN & 1 OUT

129313

DX80K9M6MP2

2.4 GHz

G

N

N

Analog &
Discrete

FlexPower

Systems

ENGINEERED

APPLICATIONS

SureCross™ Unlimited Solutions
This application employs a configurable Gateway, a FlexPower Node and a 10 to 30V dc Node. The Gateway provides two functions: first to
determine the appropriate valve control actuation and second, to extend transmission range for the application up to 6 miles. The FlexPower
Node is located in a remote location without access to power and cycles periodically to collect flow data for media. Based on this data, the
Gateway dictates the open and close action of the valve to the output on the 10 to 30V dc Node, which is located on the valve.

Model Number Frequency

Icon*

Gateway I/O

Node 1 I/O

Notes

Data Sheet

DX80K9M3PE1

900 MHz

G

N

Modbus Enabled

Discrete

2 OUT

(sinking)

Discrete

1 IN

(FlexPower™ supply

configured for MINI-BEAM)

1 IN

(passive)

DX81

Flex

Power supply

included; provides power

for

Flex

Power Node and

MINI-BEAM

129318

DX80K2M3PE1

2.4 GHz

G

N

DX80K9M3GE1

900 MHz

G

N

Discrete

2 OUT

(sinking)

Analog

2 OUT

(0-20 mA)

Discrete

2 IN (passive)

Analog

1 IN

(1

Flex

Power supply

configured to provide 15V for

500 ms every 15 minutes)

1 IN

(passive)

DX81

Flex

Power supply

included; provides power

for

Flex

Power Node and

one analog sensor

129320

DX80K2M3GE1

2.4 GHz

G

N

* = Gateway = Node † = Discrete outputs are sourcing unless otherwise noted. Analog outputs are 0-20 mA.

G

N

Discrete

Courtesy of Steven Engineering, Inc. ● 230 Ryan Way, South San Francisco, CA 94080-6370 ● General Inquiries: (800) 670-4183 ● www.stevenengineering.com

Advertising