3-18

B1272M001

BARNETT ENGINEERING LTD.

ProTalk Cv2

programming is always available if there is no Access code in the unit.

This code can be 1 to 7 digits in length and may use any of the 16 DTMF digits
including A, B, C, and D.

Default Access Code: an empty string.

Shift Change Code

The shift that is being used at any particular time is determined by the last time that a Shift
Change Code message was received. The Cv2 retains the current shift when it is powered
down and returns to that shift when power is restored. Each time a Shift Change Code is
received, the shift advances by one. If the Cv2 is currently set to shift 4 and the change
code is received, it will go to the shift 1 setting.

This code can be 1 to 7 digits in length and may use any of the 16 DTMF digits including
A, B, C, and D.

Default Shift Change Code: an empty string.

Temporary Acknowledge Time

Temporary Acknowledge time is used as a safeguard with the Acknowledge Code. When
the Temporary Acknowledge Time is set to Off it has no effect on Cv2 operations.
Normally, receipt of the Acknowledge Code for a group will cause that group to cease
alarm reporting activities until a new alarm is detected. When this control is set to any of
the four available times (30, 60, 120 and 240 minutes), receipt of the Acknowledge Code,
with the digit ‘#’ appended to it, will cause the alarm activities to cease only for the time
period set by the Temporary Time. After this timer expires, if the alarm condition has not
been removed, the Cv2 will continue alarm functions as though the Acknowledge Code had
not been received.

Default Temporary Acknowledge Time: Off

Call Progress

When Call Progress is enabled, the Cv2 will wait for the called party to speak before
beginning the voice announcement. When Call Progress is enabled, there should not be
any Answer commands directly following a Dial command in the directories.

This will

cause the Cv2 to look for a voice response twice in a row and may prevent alarm
announcements.

Default Call Progress: disabled

3.5.6 Configuration Programming

Three types of data can be transferred between the Cv2 and the programming PC. The
programming cable must be connected between the PC and the Cv2 before any data transfer is
initiated. Select the correct COM port for the attached cable in the Serial Port box.

While the serial cable is attached, the Cv2 will be in programming mode and will not be

Advertising