Convection Oven

Installation

9

be positioned in such a way that at no point does it reach a temperature which is 122°F greater than the
ambient temperature. It must be type SJTO plug 20A 250V P section 3xAWG12.

The connection to the electrical line must be made by placing an automatic switch of sufficient capacity
(see “Technical data” of the oven) and with an opening distance between contacts of at least 3 mm.

Also, during operation of the oven, the power supply must not vary from the nominal voltage value by
±10%.

The oven MUST be earthed by means of the terminal which carries the earth symbol on the connection
board.


It must also be inserted in an equipotential system (the efficiency of which must be checked in
accordance with current standards) using the terminal with the equipotential symbol. It is located near the
electrical cable entry on the panel of the oven bottom.


The manufacturer will not be held liable if this accident prevention standard is not adhered to.