Infinity Pin

Hrdwr Ref.

Hardware Specification

Notes

C1-67

Analog_In_Temp_2

12 bit A/D, 2.49K pullup to 5V

See "Air Temperature" Setup Wizard for selection.

C1-68

Analog_In_Temp_3

12 bit A/D, 2.49K pullup to 5V

Normally used for Oil Temp input.

C1-69

Stepper_2A_Out

Automotive, Programmable
Stepper Driver, up to 28V and ±1.4A

Be sure that each internal coil of the stepper
motor are properly paired with the 1A/1B and
2A/2B ECU outputs. Supports Bi-Polar stepper
motors only.

C1-70

Stepper_1A_Out

Automotive, Programmable
Stepper Driver, up to 28V and ±1.4A

Be sure that each internal coil of the stepper
motor are properly paired with the 1A/1B and
2A/2B ECU outputs. Supports Bi-Polar stepper
motors only.

C1-71

Stepper_2B_Out

Automotive, Programmable
Stepper Driver, up to 28V and ±1.4A

Be sure that each internal coil of the stepper
motor are properly paired with the 1A/1B and
2A/2B ECU outputs. Supports Bi-Polar stepper
motors only.

C1-72

Stepper_1B

Automotive, Programmable
Stepper Driver, up to 28V and ±1.4A

Be sure that each internal coil of the stepper
motor are properly paired with the 1A/1B and
2A/2B ECU outputs. Supports Bi-Polar stepper
motors only.

C1-73

Power Ground_In

Power Ground

Connect directly to battery ground

C2-1

DBW2 Motor +_Out

5.0A max Throttle Control Hbridge
Drive

+12V to open.

C2-2

DBW2 Motor -_Out

5.0A max Throttle Control Hbridge
Drive

+12V to close.

C2-3

Power Ground_In

Power Ground

Connect directly to battery ground

C2-4

Injector 7_Out

Saturated or peak and hold, 3A max
continuous

Injector 7

C2-5

Injector 8_Out

Saturated or peak and hold, 3A max
continuous

Injector 8

C2-6

Injector 9_Out

Saturated or peak and hold, 3A max
continuous

Injector 9.

C2-7

Injector 10_Out

Saturated or peak and hold, 3A max
continuous

Injector 10.

C2-8

Power Ground_In

Power Ground

Connect directly to battery ground.

C2-9

+12V_In

12 volt power from relay

12 volt power from relay. Relay must be
controlled by +12V Relay Control signal, pin C1-29
above.

C2-10

Injector 11_Out

Saturated or peak and hold, 3A max
continuous

Not used