AEM 30-3703 Infinity-8/10/12 Mini-Harness User Manual

Page 20

Advertising
background image

AEM Infinity Harness Manuals

20

© 2014 AEM Performance Electronics

Infinity Pin

Hrdwr Ref.

Hardware Specification

Notes

C2-43

LowsideSwitch_8_Out

Lowside switch, 4A max with
internal flyback diode. Inductive
load should NOT have full time
power.

12V pullup

Activates if any of the following flags are true:
OilPressProtectOut, LeanProtectOut,
CoolantProtect. Output can be assigned to other
functions. See Setup Wizard page LowSide
Assignment Tables for additional options.

C2-44

LowsideSwitch_7_Out

Lowside switch, 4A max with
internal flyback diode. Inductive
load should NOT have full time
power.

No pullup

Normally used as Spare GPO1 output.

C2-45

UEGO 2 VM_In

Bosch UEGO Controller

Virtual Ground signal. Connect to pin 5 of Bosch
UEGO sensor.

C2-46

UEGO 2 UN_In

Nernst Voltage signal. Connect to pin 1 of Bosch
UEGO sensor

C2-47

UEGO 2 IP_In

Pumping Current signal. Connect to pin 6 of Bosch
UEGO sensor

C2-48

UEGO 2 IA_In

Trim Current signal. Connect to pin 2 of Bosch
UEGO sensor

C2-49

UEGO 2 HEAT_Out

Lowside switch for UEGO heater control. Connect
to pin 4 of Bosch UEGO sensor. NOTE that pin 3 of
the Sensor is heater (+) and must be power by a
fused/switched 12V supply.

C2-50

+12V_R8C_CPU_In

Dedicated power management CPU Full time battery power. MUST be powered before

the ignition switch input is triggered (See C1-65).

C2-51

Coil 7_Out

25 mA max source current

0-5V Falling edge fire. DO NOT connect directly to
coil primary. Must use an ignitor OR CDI that
accepts a FALLING edge fire signal.

C2-52

Coil 8_Out

25 mA max source current

0-5V Falling edge fire. DO NOT connect directly to
coil primary. Must use an ignitor OR CDI that
accepts a FALLING edge fire signal.

C2-53

Coil 9_Out

25 mA max source current

0-5V Falling edge fire. DO NOT connect directly to
coil primary. Must use an ignitor OR CDI that
accepts a FALLING edge fire signal.

C2-54

Coil 10_Out

25 mA max source current

0-5V Falling edge fire. DO NOT connect directly to
coil primary. Must use an ignitor OR CDI that
accepts a FALLING edge fire signal.