AEM 30-3703 Infinity-8/10/12 Mini-Harness User Manual

Page 17

Advertising
background image

17

© 2014 AEM Performance Electronics

Infinity Pin

Hrdwr Ref.

Hardware Specification

Notes

C2-11

Injector 12_Out

Saturated or peak and hold, 3A max
continuous

Not used

C2-12

Analog_In_17

12 bit A/D, 100K pullup to 5V

0-5V analog signal. Use +5V Out pins as power
supply and Sensor Ground pins as the low
reference. Do not connect signals referenced to
+12V as this can permanently damage the ECU.
Normally used as A/C Analog Request input.

C2-13

Analog_In_18

12 bit A/D, 100K pullup to 5V

0-5V analog signal. Use +5V Out pins as power
supply and Sensor Ground pins as the low
reference. Do not connect signals referenced to
+12V as this can permanently damage the ECU.
Normally used as DBW APP1.

C2-14

Analog_In_19

12 bit A/D, 100K pullup to 5V

0-5V analog signal. Use +5V Out pins as power
supply and Sensor Ground pins as the low
reference. Do not connect signals referenced to
+12V as this can permanently damage the ECU.
Normally used as DBW APP2.

C2-15

Analog_In_Temp_4

12 bit A/D, 2.49K pullup to 5V

Normally used as Charge Out Temperature input.

C2-16

Analog_In_Temp_5

12 bit A/D, 2.49K pullup to 5V

Normally used as Airbox Temperature input.

C2-17

Analog_In_Temp_6

12 bit A/D, 2.49K pullup to 5V

Normally used as Fuel Temperature input.

C2-18

Analog_In_13

12 bit A/D, 100K pullup to 5V

0-5V analog signal. Use +5V Out pins as power
supply and Sensor Ground pins as the low
reference. Do not connect signals referenced to
+12V as this can permanently damage the ECU.
See Setup Wizard Oil Pressure page for setup
options. See OilPressure [psig] for channel data.

C2-19

Analog_In_14

12 bit A/D, 100K pullup to 5V

0-5V analog signal. Use +5V Out pins as power
supply and Sensor Ground pins as the low
reference. Do not connect signals referenced to
+12V as this can permanently damage the ECU.

Advertising