Infinity supported application 15 – AEM Infinity Supported Applications - Dodge 2008-2010 Viper 4G User Manual

Page 15

Advertising
background image

Infinity Supported Application

15

© 2014 AEM Performance Electronics

Infinity

Pin

Hardware Reference

08–10 Dodge

Viper Function

08–10

Dodge

Viper Pin

Destination

Hardware Specification

Notes

C1-68

Harness_Analog_In_Te
mp_3

Oil Temperature

Sensor

C3-33

12 bit A/D, 2.49K pullup to
5V

See 1D table OilTempCal table f or
calibration data and OilTemp [C] f or
channel data.

C1-69

Stepper_2A

Stepper 2A

Automotiv e, Programmable
Stepper Driv er, up to 28V
and ±1.4A

Be sure that each internal coil of the
stepper motor is properly paired with
the 1A/1B and 2A/2B ECU outputs.
Supports Bi-Polar stepper motors only .

C1-70

Stepper_1A

Stepper 1A

Automotiv e, Programmable
Stepper Driv er, up to 28V
and ±1.4A

Be sure that each internal coil of the
stepper motor is properly paired with
the 1A/1B and 2A/2B ECU outputs.
Supports Bi-Polar stepper motors only .

C1-71

Stepper_2B

Stepper 2B

Automotiv e, Programmable
Stepper Driv er, up to 28V
and ±1.4A

Be sure that each internal coil of the
stepper motor is properly paired with
the 1A/1B and 2A/2B ECU outputs.
Supports Bi-Polar stepper motors only .

C1-72

Stepper_1B

Stepper 1B

Automotiv e, Programmable
Stepper Driv er, up to 28V
and ±1.4A

Be sure that each internal coil of the
stepper motor is properly paired with
the 1A/1B and 2A/2B ECU outputs.
Supports Bi-Polar stepper motors only .

C1-73

Power Ground

Ground

Power Ground

Connect directly to battery ground.

C2-1

DBW2 Motor +

DBW Motor

Control Open

C2-8

5.0A max Throttle Control
Hbridge Driv e

+12V to open

C2-2

DBW2 Motor -

DBW Motor

Control Close

C2-18

5.0A max Throttle Control
Hbridge Driv e

+12V to close

C2-3

Power Ground

Ground

C3-31

Power Ground

Connect directly to battery ground.

C2-4

Injector 7

Injector 7

C1-5

Saturated or peak and hold,
3A max continuous

Injector 7

C2-5

Injector 8

Injector 8

C2-13

Saturated or peak and hold,
3A max continuous

Injector 8

C2-6

Injector 9

Injector 9

C1-4

Saturated or peak and hold,
3A max continuous

Injector 9

C2-7

Injector 10

Injector 10

C2-12

Saturated or peak and hold,
3A max continuous

Injector 10

C2-8

Power Ground

Ground

Pin 2 & 3 of

V23374-

A1601-X008

Relay

Power Ground

Connect directly to battery ground.

C2-9

+12V

+12V In

C2-19 / C2-

38

12 v olt power f rom relay

12 v olt power f rom relay . Relay must
be controlled by +12V Relay Control
signal, pin C1-29 abov e.

Advertising