Infinity supported application 19 – AEM Infinity Supported Applications - Dodge 2008-2010 Viper 4G User Manual

Page 19

Advertising
background image

Infinity Supported Application

19

© 2014 AEM Performance Electronics

Infinity

Pin

Hardware Reference

08–10 Dodge

Viper Function

08–10

Dodge

Viper Pin

Destination

Hardware Specification

Notes

C2-43

LowsideSwitch_8

RAD Fan Relay
/ Control Engine

Protect Out

C4-3

Lowside switch, 4A max
with internal f ly back diode.
Inductiv e load should NOT
hav e f ull time power.

See Spare GPO1 Basic Setup section
of User GPIOs and PWM Setup Wizard
page LowSide Assignment Tables f or
additional options.
Activ ates if any of the f ollowing f lags
are true: OilPressProtectOut,
LeanProtectOut, CoolantProtect.
Output can be assigned to other
f unctions. See Setup Wizard page
LowSide Assignment Tables f or
additional options.

C2-44

LowsideSwitch_7

Rev erse Lock-

Out Control

C4-1

Lowside switch, 4A max
with internal f ly back diode.
Inductiv e load should NOT
hav e f ull time power.

See Spare GPO1 Basic Setup section
of User GPIOs and PWM Setup Wizard
page LowSide Assignment Tables f or
additional options.

C2-45

UEGO 2 VM

UEGO 2 VM

Bosch UEGO Controller

Virtual Ground signal. Connect to pin 5
of Bosch UEGO sensor.

C2-46

UEGO 2 UN

UEGO 2 UN

Nernst Voltage signal. Connect to pin 1
of Bosch UEGO sensor.

C2-47

UEGO 2 IP

UEGO 2 IP

Pumping Current signal. Connect to pin
6 of Bosch UEGO sensor.

C2-48

UEGO 2 IA

UEGO 2 IA

Trim Current signal. Connect to pin 2 of
Bosch UEGO sensor.

C2-49

UEGO 2 HEAT

UEGO 2 HEAT

Lowside switch f or UEGO heater
control. Connect to pin 4 of Bosch
UEGO sensor. NOTE that pin 3 of the
Sensor is heater (+) and must be power
by a f used/switched 12V supply .

C2-50

+12V_R8C_CPU

Battery Perm

Power

Dedicated power
management CPU

Optional f ull time battery power. MUST
be powered bef ore the ignition switch
input is triggered. (See C1-65.)

C2-51

Coil 7

Coil 7

C1-2

25 mA max source current

0–5V Falling edge f ire. DO NOT
connect directly to coil primary . Must
use an ignitor OR CDI that accepts a
FALLING edge f ire signal.

C2-52

Coil 8

Coil 8

C2-3

25 mA max source current

0–5V Falling edge f ire. DO NOT
connect directly to coil primary . Must
use an ignitor OR CDI that accepts a
FALLING edge f ire signal.

C2-53

Coil 9

Coil 9

C1-1

25 mA max source current

0–5V Falling edge f ire. DO NOT
connect directly to coil primary . Must
use an ignitor OR CDI that accepts a
FALLING edge f ire signal.

C2-54

Coil 10

Coil 10

C2-2

25 mA max source current

0–5V Falling edge f ire. DO NOT
connect directly to coil primary . Must
use an ignitor OR CDI that accepts a
FALLING edge f ire signal.

Advertising