16

© 2014 AEM Performance Electronics

Infinity

Pin

Hardware Reference

08–10 Dodge

Viper Function

08–10

Dodge

Viper Pin

Destination

Hardware Specification

Notes

C2-10

Injector 11

Injector 11

Saturated or peak and hold,
3A max continuous

Not used

C2-11

Injector 12

Injector 12

Saturated or peak and hold,
3A max continuous

Not used

C2-12

Analog_In_17

A/C Analog

Request

12 bit A/D, 100K pullup to
5V

0–5V analog signal. Use +5V Out pins
as power supply and Sensor Ground
pins as the low ref erence. Do not
connect signals ref erenced to +12V as
this can permanently damage the ECU.
See Setup Wizard Input Functions page
f or input selection. See AC_Request_In
1-axis table f or activ ation logic.

C2-13

Analog_In_18

DBW_APP1 [%]

C2-21

12 bit A/D, 100K pullup to
5V

0–5V analog signal. Use +5V Out pins
as power supply and Sensor Ground
pins as the low ref erence. Do not
connect signals ref erenced to +12V as
this can permanently damage the ECU.

C2-14

Analog_In_19

DBW_APP2 [%]

C1-32

12 bit A/D, 100K pullup to
5V

0–5V analog signal. Use +5V Out pins
as power supply and Sensor Ground
pins as the low ref erence. Do not
connect signals ref erenced to +12V as
this can permanently damage the ECU.

C2-15

Analog_In_Temp_4

Charge Out

Temperature

12 bit A/D, 2.49K pullup to
5V

See ChargeOutTemp [C] table f or
calibration data and ChargeOutTemp
[C] f or channel data.

C2-16

Analog_In_Temp_5

Airbox Temp /

Intake Air

Temperature

C1-16

12 bit A/D, 2.49K pullup to
5V

See AirboxTemp [C] table f or
calibration data and AirboxTemp [C] f or
channel data.

C2-17

Analog_In_Temp_6

Fuel

Temperature

12 bit A/D, 2.49K pullup to
5V

See FuelTemp [C] table f or calibration
data and FuelTemp [C] f or channel
data.

C2-18

Analog_In_13

Oil Pressure

C3-23

12 bit A/D, 100K pullup to
5V

0–5V analog signal. Use +5V Out pins
as power supply and Sensor Ground
pins as the low ref erence. Do not
connect signals ref erenced to +12V as
this can permanently damage the ECU.
See Setup Wizard Oil Pressure page f or
setup options. See OilPressure [psig]
f or channel data.

C2-19

Analog_In_14

Traction Control

Mode /

Sensitiv ity

12 bit A/D, 100K pullup to
5V

0–5V analog signal. Use +5V Out pins
as power supply and Sensor Ground
pins as the low ref erence. Do not
connect signals ref erenced to +12V as
this can permanently damage the ECU.
See the TC_SlipTrgtTrim [MPH] 1-axis
table. A multi-position rotary switch
such as AEM P/N 30-2056 is
recommended.

Advertising