Infinity supported application 11 – AEM Infinity Supported Applications - Dodge 2008-2010 Viper 4G User Manual

Page 11

Advertising
background image

Infinity Supported Application

11

© 2014 AEM Performance Electronics

Infinity

Pin

Hardware Reference

08–10 Dodge

Viper Function

08–10

Dodge

Viper Pin

Destination

Hardware Specification

Notes

C1-18

LowsideSwitch_3

MIL Output

Lowside switch, 4A max
with internal f ly back diode.
Inductiv e load should NOT
hav e f ull time power.

See Wizard page "LowSide Assignment
Tables" f or output assignment.
MIL Activ ates when any of the
f ollowing f lags are true: ErrorAirTemp,
ErrorBaro, ErrorCoolantTemp,
ErrorEBP, ErrorFuelPressure,
UEGO_0_Diag_error,
UEGO_1_Diag_error, ErrorMAFAnalog,
ErrorMAFDigital, ErrorMAP,
ErrorOilPressure, ErrorThrottle.

C1-19

AGND_1

Sensor Ground

C1-17 / C1-

23

Dedicated analog ground

Analog 0–5V sensor ground

C1-20

AGND_1

Sensor Ground

C1-18

Dedicated analog ground

Analog 0–5V sensor ground

C1-21

Crankshaf t Position
Sensor Hall

Crankshaf t

Position Sensor

Hall

C1-25

10K pullup to 12V. Will work
with ground or f loating
switches.

See Setup Wizard page Cam/Crank f or
options.

C1-22

Camshaf t Position
Sensor 1 Hall

Camshaf t

Position Sensor

1 Hall

C1-22

10K pullup to 12V. Will work
with ground or f loating
switches.

See Setup Wizard page Cam/Crank f or
options.

C1-23

Digital_In_2

Camshaf t

Position Sensor

2 Hall

10K pullup to 12V. Will work
with ground or f loating
switches.

See Setup Wizard page Cam/Crank f or
options.

C1-24

Digital_In_3

Turbo Speed Hz

10K pullup to 12V. Will work
with ground or f loating
switches.

See Setup Wizard page Input Function
Assignment f or calibration constant.
TurboSpeed [RPM] = Turbo [Hz] * Turbo
Speed Calibration.

C1-25

Digital_In_4

Vehicle Speed

Sensor

C4-29

10K pullup to 12V. Will work
with ground or f loating
switches.

See Setup Wizard page Input Function
Assignment f or calibration constant.

C1-26

Digital_In_5

Flex Fuel

10K pullup to 12V. Will work
with ground or f loating
switches.

See channel FlexDigitalIn [Hz] f or raw
f requency input data.

C1-27

Knock Sensor 1

Knock Sensor 1

C3-34

Dedicated knock signal
processor

See Setup Wizard page Knock Setup
f or options.

C1-28

Knock Sensor 2

Knock Sensor 2

C3-26

Dedicated knock signal
processor

See Setup Wizard page Knock Setup
f or options.

C1-29

+12V_Relay _Control

+12V Relay

Control

C3-19 / C2-

17

0.7A max ground sink f or
external relay control

Will activ ate at key on and at key of f
according to the conf iguration settings.

C1-30

Power Ground

Ground

C3-27

Power Ground

Connect directly to battery ground.

C1-31

CANL_Aout

AEMNet CANL

Dedicated High Speed CAN
Transceiv er

Recommend twisted pair (one twist per
2") with terminating resistor. Contact
AEM f or additional inf ormation.

Advertising