AEM Infinity Supported Applications - Honda H-Series Engine User Manual

Page 14

Advertising
background image

14

© 2014 AEM Performance Electronics

Infinity

Pin

Hardware Reference

7100-XXXX-62
7101-XXXX-63

Function

Dest.

Pin

Honda
OBD 1

Dest.

Pin

Honda

OBD

2a

Dest.

Pin

Honda

OBD

2b

Hardware

Specification

Notes

C2-29

LowsideSwitch_9

Tachometer

A19

Lowside switch,
4A max with
internal f ly back
diode, 2.2K 12V
pullup. Inductiv e
load should NOT
hav e f ull time
power.

See Setup Wizard page
Tacho f or conf iguration
options.

C2-30

AGND_2

Sensor Ground

Dedicated
analog ground

Analog 0–5V sensor ground

C2-31

AGND_2

Sensor Ground

Dedicated
analog ground

Analog 0–5V sensor ground

C2-32

AGND_2

Sensor Ground

Dedicated
analog ground

Analog 0–5V sensor ground

C2-33

Analog_In_20

Spare Analog Input

12 bit A/D, 100K
pullup to 5V

0–5V analog signal. Use +5V
Out pins as power supply
and Sensor Ground pins as
the low ref erence. Do not
connect signals ref erenced
to +12V as this can
permanently damage the
ECU.

C2-34

Analog_In_21

3 Step Enable

Switch

12 bit A/D, 100K
pullup to 5V

0–5V analog signal. Use +5V
Out pins as power supply
and Sensor Ground pins as
the low ref erence. Do not
connect signals ref erenced
to +12V as this can
permanently damage the
ECU. See 3StepSwitch 1-
axis table f or setup.

C2-35

Analog_In_22

USB Logging

Activ ate

12 bit A/D, 100K
pullup to 5V

0–5V analog signal. Use +5V
Out pins as power supply
and Sensor Ground pins as
the low ref erence. Do not
connect signals ref erenced
to +12V as this can
permanently damage the
ECU. See
USBLoggingRequestIn
channel f or input state. See
Setup Wizard page USB
Logging f or conf iguration
options.

C2-36

Analog_In_23

Charge Out

Pressure

12 bit A/D, 100K
pullup to 5V

0–5V analog signal. Use +5V
Out pins as power supply
and Sensor Ground pins as
the low ref erence. Do not
connect signals ref erenced
to +12V as this can
permanently damage the
ECU. See ChargeOutPress
[kPa] channel f or input state.
See Setup Wizard page
Charge Out Pressure f or
calibration options.

Advertising