Infinity supported application 15 – AEM Infinity Supported Applications - Honda H-Series Engine User Manual

Page 15

Advertising
background image

Infinity Supported Application

15

© 2014 AEM Performance Electronics

Infinity

Pin

Hardware Reference

7100-XXXX-62
7101-XXXX-63

Function

Dest.

Pin

Honda
OBD 1

Dest.

Pin

Honda

OBD

2a

Dest.

Pin

Honda

OBD

2b

Hardware

Specification

Notes

C2-37

Digital_In_6

Spare Digital Input

B5

C5

A27

No pullup. Will
work with TTL
signals.

Input can be assigned to
dif f erent pins. See Setup
Wizard page Input Function
Assignments f or input
mapping options.

C2-38

Digital_In_7

Clutch Switch

No pullup. Will
work with TTL
signals.

See ClutchSwitch 1-axis
table f or setup options. Input
can be assigned to dif f erent
pins. See Setup Wizard page
Input Function Assignments
f or input mapping options.

C2-39

Power Ground

Ground

Power Ground

Connect directly to battery
ground.

C2-40

Power Ground

Ground

Power Ground

Connect directly to battery
ground.

C2-41

CanH_Bout

CANH

Dedicated High
Speed CAN
Transceiv er

Not used

C2-42

CanL_Bout

CANL

Dedicated High
Speed CAN
Transceiv er

Not used

C2-43

LowsideSwitch_8

Engine Protect

Warning Out

Lowside switch,
4A max with
internal f ly back
diode. Inductiv e
load should NOT
hav e f ull time
power.

Activ ates if any of the
f ollowing f lags are true:
OilPressProtectOut,
LeanProtectOut,
CoolantProtect. Output can
be assigned to other
f unctions. See Setup Wizard
page LowSide Assignment
Tables f or additional options.

C2-44

LowsideSwitch_7

Spare GPO1

Lowside switch,
4A max with
internal f ly back
diode. Inductiv e
load should NOT
hav e f ull time
power.

See Spare GPO1 Basic
Setup section of User GPIOs
and PWM Setup Wizard page
LowSide Assignment Tables
f or additional options.

C2-45

UEGO 2 VM

UEGO 2 VM

Bosch UEGO
Controller

Virtual Ground signal.
Connect to pin 5 of Bosch
UEGO sensor.

C2-46

UEGO 2 UN

UEGO 2 UN

Nernst Voltage signal.
Connect to pin 1 of Bosch
UEGO sensor

C2-47

UEGO 2 IP

UEGO 2 IP

Pumping Current signal.
Connect to pin 6 of Bosch
UEGO sensor

C2-48

UEGO 2 IA

UEGO 2 IA

Trim Current signal. Connect
to pin 2 of Bosch UEGO
sensor

C2-49

UEGO 2 HEAT

UEGO 2 HEAT

Lowside switch f or UEGO
heater control. Connect to
pin 4 of Bosch UEGO
sensor. NOTE that pin 3 of
the Sensor is heater (+) and
must be power by a f used/
switched 12V supply .

Advertising