background image

Infinity Supported Application

11

© 2014 AEM Performance Electronics

Infinity

Pin

Hardware

Reference

7100-XXXX-62
7101-XXXX-63

Function

Dest.

Pin

Evo

VIII

Dest.

Pin

Evo IX

Hardware Specification

Notes

C1-9

Flash_Enable

Flash Enable

10K pulldown

Not usually needed f or automatic
f irmware updates through Inf inity
Tuner. If connection errors occur
during update, connect 12 v olts to
this pin bef ore proceeding with
upgrade. Disconnect the 12 v olts
signal af ter the update.

C1-10

+12V_R8C_CPU

Battery Perm

Power

80

60

Dedicated power management
CPU

Full time battery power. MUST be
powered bef ore the ignition switch
input is triggered. (See C1-65.)

C1-11

Coil 4

Coil 4

25 mA max source current

0–5V Falling edge f ire. DO NOT
connect directly to coil primary . Must
use an ignitor OR CDI that accepts a
FALLING edge f ire signal.

C1-12

Coil 3

Coil 3

25 mA max source current

0–5V Falling edge f ire. DO NOT
connect directly to coil primary . Must
use an ignitor OR CDI that accepts a
FALLING edge f ire signal.

C1-13

Coil 2

Coil 2

23

12

25 mA max source current

0–5V Falling edge f ire. DO NOT
connect directly to coil primary . Must
use an ignitor OR CDI that accepts a
FALLING edge f ire signal.

C1-14

Coil 1

Coil 1

10

11

25 mA max source current

0–5V Falling edge f ire. DO NOT
connect directly to coil primary . Must
use an ignitor OR CDI that accepts a
FALLING edge f ire signal.

C1-15

Coil 6

Coil 6

25 mA max source current

0–5V Falling edge f ire. DO NOT
connect directly to coil primary . Must
use an ignitor OR CDI that accepts a
FALLING edge f ire signal.

C1-16

Coil 5

Coil 5

25 mA max source current

0–5V Falling edge f ire. DO NOT
connect directly to coil primary . Must
use an ignitor OR CDI that accepts a
FALLING edge f ire signal.

C1-17

LowsideSwitch_2

Coolant Fan 1

Control

32, 34

30, 31

Lowside switch, 4A max, NO
internal f ly back diode.

See "LowSide Assignment Tables" f or
output assignment.

C1-18

LowsideSwitch_3

MIL Output

36

22

Lowside switch, 4A max with
internal f ly back diode.
Inductiv e load should NOT
hav e f ull time power.

See Wizard page "LowSide
Assignment Tables" f or output
assignment.
MIL Activ ates when any of the
f ollowing f lags are true: ErrorAirTemp,
ErrorBaro, ErrorCoolantTemp,
ErrorEBP, ErrorFuelPressure,
UEGO_0_Diag_error,
UEGO_1_Diag_error,
ErrorMAFAnalog, ErrorMAFDigital,
ErrorMAP, ErrorOilPressure,
ErrorThrottle.

C1-19

AGND_1

Sensor Ground

92

49

Dedicated analog ground

Analog 0–5V sensor ground