Input function assignments, A/c setup, Lowside assignment tables – AEM Infinity Supported Applications - Mitsubishi 2006 Evolution IX Engine User Manual

Page 6: Radiator fan control

Advertising
background image

6

© 2014 AEM Performance Electronics

Input Function Assignments

In the Wizard Input Function Assignments tab confirm the following setting:

AC Request Switch Setup = Digital 6

A/C Setup

Add a 1D Table for AC_Request_In. Populate the table as shown below.

LowSide Assignment Tables

In the Wizard Output Functions tab confirm the following settings:

LS5 Setup (Coolant Fan):

Frequency

= 20 Hz

LS5_Duty X-Axis

= Vehicle Speed (reassignable)

LS5_Duty Y-Axis

= Coolant Temp [C]

LS8 Setup (VVC1A):

Frequency

= 250 Hz

LS8_Duty X-Axis

= Engine Speed [RPM]

LS8_Duty Y-Axis

= VVC1A_Duty [%]

Radiator Fan Control

Populate the 2D LS5_Duty [%] table similar to the table below. A higher value in the LS5_Duty [%] table
will result in a faster fan speed (0% duty = max fan speed, 100% duty = fan off).

Advertising