ALL300 TROUBLESHOOTING GUIDE

TECH SUPPORT: (877) 287-4601 Monday through Friday 8:00am to 4:00pm CST

I. Troubleshooting and installation must be performed by a licensed, bonded, and insured electrician.

Electricity can cause death, personal injury, and/or property damage.

II. To perform most troubleshooting procedures, the following tools will be needed:

a. 5/16” nut driver or 5/16” socket and ratchet

b. Volt Meter

c. 14 AWG jumper wire

III. Prior to troubleshooting or installation, read, understand and follow each safety warning in the ALL300

installation instructions and safety precautions supplement. Failure to follow Aladdin’s safety precautions

and/or warnings could cause the chandelier to fall, which could cause death, injury, and/or property damage.

SYMPTOM: ALL300 DOES NOT OPERATE:

Once ALL300 is installed per the installation instructions, use the following steps to troubleshoot.

1. Confirm motor switch in the square box is turned on. The square box is mounted on the chassis plate of

the ALL300, right in front of the control board. If it was found in the off position, flip it to the on position

and use the controller to test the ALL300. If ALL300 still does not operate, proceed to step 2.

2. Turn the motor and light switch in the square box to the off position. Using the 5/16” nut driver or

socket, remove control board cover. Confirm motor fuse is good. The motor fuse is held to the control

board by fuse clips and is located right in front of the motor assembly. Remove and perform a continuity test

on the motor fuse. If the fuse reads continuity, place it back in the fuse clips. If it does not read continuity,

it must be replaced with a good, 1 amp, slow blow fuse. Turn the motor and light switch in the square box

to the on position, and use controller to test the ALL300. If the ALL300 still does not operate, proceed to

step 3.

3. Turn the motor and light switch in the square box to the off position. Confirm limit switch wires are

attached properly. Confirm the limit switch wires are properly connected to the limit switch as well as the

limit switch terminals on the control board. The limit switch is located on top of the ceiling box. The purple

or white limit switch wire should be plugged from COM on the control board to the single terminal side

of one limit switch. The orange or green limit switch wire should be plugged from NO on the control board

to the top limit switch terminal on the double terminal side of the limit switch. The brown or red limit

switch wire should be plugged from NC on the control board to the bottom limit switch terminal on the

double terminal side of the limit switch. If limit wires were found plugged incorrectly, plug them to their

corresponding terminal and use the controller to test the ALL300. If the ALL300 still does not operate,

proceed to step 4.

4. From where the ALL300 is installed, call Aladdin Light Lift technical support Monday through Friday

during normal business hours at (877) 287-4601.

SYMPTOM: CHANDELIER WILL NOT LIGHT:

Once the ALL300 is installed per the installation instructions, use the following steps to troubleshoot.

Note: If the top contact plate is painted, the chandelier will not light.