Step 11, Step 12 – Aladdin Light Lift ALL300-CM User Manual

Page 7

Advertising
background image

STEP 11

Turn off supply power before wiring ALL300. Turn off motor switch in square box. Wire motor switch

with 110V wiring. The 110V motor feed must be kept separate from 110V light switch leg. Keep motor

and light neutrals separate. The motor neutral is white and 14 gauge. See Diagram G.

Never wire the ALL300 improperly. Make sure electricity is turned off when installing and/or

performing maintenance on the ALL300. Improper wiring and/or electricity could cause death,

personal injury, and/or property damage.

STEP 12

Turn off supply power before wiring ALL300. Turn off light switch in square box. Wire light switch with

110V wiring. The 110V light switch leg can not be used as motor feed. Keep light and motor neutrals

separate. The light neutral is white and 12 gauge. If wired properly, a dimmer may be used. Wire a two-

circuit light package on seperate phases for lights (2 hots - 1 neutral). See Diagram G.

Never wire the ALL300 improperly. Make sure electricity is turned off when installing and/or

performing maintenance on the ALL300. Improper wiring and/or electricity could cause death,

personal injury, and/or property damage.

12 Gauge Light Neutral

14 Gauge Motor Neutral

14 Gauge Motor Hot

12 Gauge Light Hot

110V House Hot

For Motor

110V House Neutral

For Motor

Neutral Light

Switch Leg 110V

Hot Light Switch

Leg 110V

Diagram G

Light

Motor

Advertising
This manual is related to the following products: