3.0 Maintenance and Storage

3.2 Cleaning

1. ALWAYS INSPECT YOUR CLEAN AIR FLOW

TM

PAPR system after

cleaning.

Clean the external surfaces of the Clean Air Flow

TM

system and the

battery pack with a soft cloth dampened in a mild solution of clean water and
mild detergent. Abrasive cleaners should never be used. During cleaning,
ensure that NO water is allowed to enter into the blower unit or battery
pack,this could damage the blower unit’s internal parts. The unit should never
be immersed in any type of liquid.

Example of Record

*THIS IS ONLY AN EXAMPLE - Regulatory Guidance can be found in the
following documents: OSHA 29 CFR 1910 Part 134 and ANSI Z88.2

Do

Not

Allow

contaminants to enter into the breathing

tube or blower unit. Failure to prevent contaminants from
entering into the breathing tube or turbo unit could lead
to contaminant exposure resulting in serious bodily injury
or loss of life. Consult your local safety professional in
the event contaminant entry in the breathing tube of the
blower unit is suspected.

3.1 Record Keeping

All components should be checked daily when used regularly. Regardless of
usage, each unit requires a documented monthly inspection of all aspects relat-
ing to safety. A trained and competent person with full knowledge of respiratory
equipment should carry this out. Records should be maintained throughout the
life of the equipment.

DATE AUTO LENS HELMET FACE COLLAR BREATHING TUBE SEALS FLOW RATE BATTERY BATTERY

CHARGER INITIAL