20. TEMPERATURE CONTROL CONVERSION CHART - OHMS TO DEGREES

The temperature sensor (probe) that is supplied with this conveyor oven is an RTD type, which yields an

output based on Ohms of resistance. This particular RTD device has a linear resistance curve that

produces a very predictable amount of resistance that can be converted to degrees Fahrenheit. This

particular device produces a resistance increase of 2 Ohms per every 1 degree F. The baseline value is

approx. 1000 ohms at 32 °F (0°C).

22

Ohms

°F

Ohms

°F

Ohms

°F

1002

1004

1017

1025

1038

1046

1059

1067

1080

1088

1101

1109

1122

1130

1143

1151

1164

1172

1184

1193

1205

1214

1226

1234

1247

1255

1267

1276

1288

1286

1309

1317

1329

1338

1350

1358

1370

1379

1391

1399

32

34

40

44

50

54

60

64

70

74

80

84

90

94

100

104

110

114

120

124

130

134

140

144

150

154

160

164

170

174

180

184

190

194

200

204

210

214

220

224

1411

1420

1432

1440

1452

1460

1473

1481

1493

1501

1513

1521

1533

1541

1554

1562

1574

1582

1594

1602

1614

1622

1634

1642

1654

1662

1674

1682

1694

1702

1714

1722

1734

1742

1753

1761

1773

1781

1793

1801

230

234

240

244

250

254

260

264

270

274

280

284

290

294

300

304

310

314

320

324

330

334

340

344

350

354

360

364

370

374

380

384

390

394

400

404

410

414

420

424

1813

1821

1832

1844

1852

1860

1872

1879

1891

1899

1911

1918

1930

1938

1950

1957

1969

1977

1988

1996

2008

2027

2035

2046

2054

2066

2073

2085

2093

2105

2112

2124

2132

2144

2151

2163

2171

2182

2190

2202

430

434

440

446

450

454

460

464

470

474

480

484

490

494

500

504

510

514

520

524

530

540

544

550

554

560

564

570

574

580

584

590

594

600

604

610

614

620

624

630

Advertising