Gp-6 cabmaker operation and adjustment – Barranca Diamond GP-6 Cabmaker User Manual

Page 13

Advertising
background image

13

PUMP SET-UP

A submersible electric water pump is used to supply water to the polishing wheels as coolant and

lubricant. The pump has a flow control adjustment on one side and should be adjusted for maximum

water intake (Fig 10). It is recommended that a 5 gallon bucket be used as a water reservoir into which

the submersible pump should be placed. The level of the reservoir water should be monitored so that

water the pump always remains fully submerged.

Fig 9 - Pump inlet adjustment set to

minimum flow

Fig 10 - Pump inlet adjustment set to

maximum flow

Fig 11 - Pump hose attached to water

pump outlet

Connect the pump to the brass ON/OFF barbed lever valve at the rear of the hood with the included

1/4" ID water hose. Insert one end of the 1/4" ID water hose over the water pump outlet (Fig 11) and

the other end over the barbed end of the water valve inlet (Fig 12).

Fig 12 - Water valve in the open

position

Fig 13 - Electrical outlet for water

pump

The pump can be plugged into the female receptacle plug accessory attached to the main switch box

(Fig 13) when using the GP-6 Cabmaker. Power to run the pump will occur once the switch box lever

is placed in the ON position. The pump should be operated in maximum flow setting. This will allow

sufficient water to reach the valve on the rear of the hood to provide water to each of the three needle

valves that control water flow to each of the three work stations.

GP-6 CABMAKER

OPERATION AND ADJUSTMENT

Advertising