Ramp Dwell Programming

12

MC16-GB-C

– 1.04

5.7

Timer Function Table

T.tYP

On Pressing the

Timer key

During the

Countdown

On completion

of the

Countdown

T1

Output

On

On

Off

Timer

Starts when Setpoint

reached

Counts Down

Off

Display

Flashes

t1 3 times.

Shows Time left for 3 secs.

PV

Cycling PV / End

Timer

Indicator

Flashing until setpoint

reached

On

Off

t2

Output

On

On

Off

Timer

Start Immediately

Counts Down

Off

Display

Flashes

t2 3 times

Shows Time left for 3 secs

PV

Cycling PV / End

Timer

Indicator

On

On

Off

t3

Output

Off

Off

On

Timer

Start Immediately

Counts Down

Off

Display

Flashes

t3 3 times

Shows Time Remaining

Time Remaining

END shows 3 secs then

PV

Timer

Indicator

On

On

Off

t4

Output

On

On

On

Timer

Starts when Setpoint

reached

Counts Down

Off

Display

Flashes

t4 3 times

Shows Time left for 3 secs

PV

Cycling PV / End

Timer

Indicator

Flashing until setpoint

reached

On

Off

t5

Output

On

On

On

Timer

Start Immediately

Counts Down

Off

Display

Flashes

t5 3 times

Shows Time left for 3 secs

PV

Cycling PV / End

Timer

Indicator

On

On

Off

Advertising