Arm Calibration

Important: Always perform the Arm Calibration imme-

diately after Machine Calibration. The balancer software

will not permit it otherwise. During Machine Calibration,

the balancer software calculates both the A (offset) and

W (width) dimensions. The Arm Calibration gives the

balancer software a reference point to the edge of the

faceplate and home position. When the user enters the

A dimension from the arm rod, it calculates the differ-

ence from the Machine Calibration A and uses that as a

factor for the manual A entry. Arm Calibration also gives

the D dimension a reference point from home position.

1.

Complete the Machine Calibration procedure (see

page 17).

2.

Press and hold the Function key and Calibration

key for three (3) seconds to select the Arm Calibration

mode.

3.

Bring the tip edge of the arm precisely to the outer

edge of the faceplate and hold it there while pressing

the Function key. If necessary to reach the faceplate

accurately, loosen the calibration wheel temporarily.

4.

With the arm still at the edge of the faceplate,

press A key and use UP / DOWN arrow to adjust A

dimension value as shown on arm gauge. Display will

show at static position of LED. Press Function key.

Figure 26 - While holding Arm At Faceplate Edge, Enter A

5.

Move the arm to its home position and press the

Function key.

6.

Move the arm to the clip-on weight location on the

rim flange and hold it there; press D key and use UP /

DOWN arrows to adjust the D dimension value. Display

will show at static position of LED. Press Function key.

7.

While still holding the arm at the clip-on weight

position on the wheel, press A key and use UP / DOWN

arrows to adjust the A dimension value as read off the

arm gauge. Press Function key.

8.

Return arm to home position.

9.

When machine displays “END”, the Arm Calibration

is complete. Press FUNCTION to exit.

Important: To redo the Arm Calibration procedure,

press and hold FUNCTION and press “Clip 1” for 3

seconds to enter CDE mode, then press “T1 Tape” then

press “W” to bypass the Machine Calibration require-

ment. Always use the same wheel assembly that was

used during the Machine Calibration or else the calibra-

tion will not be correct.

Hold Arm

Tip Edge

At Edge Of

Faceplate

Enter A

Value

Shown On

Arm Gauge