Important: Always read and follow instructions.

• 21

Error

Description

100, N01, CAL Exceeded 5 degree range

between placement of calibration

weight from outside flange to

inside flange.

100, N02, CAL Calibration wheel is more than

1-ounce out of balance. Calibration

is rejected.

100, N03, CAL Calibration wheel is more than

0.25-ounce but less than 1-ounce

out of balance. Calibration is

stored, but with warning.

Overload Protection - The balancer’s motor is over-

load protected per UL requirements. After 4 to 5 min-

utes the machine automatically resets itself; activating

the fan motor. If this happens, notify your Certified

Service Partner immediately.

Important: Allow the fan to cool the motor for at least

30 minutes before using the balancer so the overload

protection is not tripped again.